Descargar Imprimir esta página

Klafs SL 028 Instrucciones De Operación página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

SL 028
7.
If something does not work
Error
The control
system cannot be
switched On.
The cabin does
not warm up.
The cabin light
does not turn On.
50701101/02.13
Repair and maintenance is to be carried out exclusively by Klafs' service
personnel or by personnel expressly authorized by Klafs!
Cause
No mains voltage.
Room temperature of the
control system <0 ºC or
>25 ºC.
The safety temperature limiter
(STL) tripped.
The main switch is not
switched On or the controller
of the bathing temperature is
all the way to the left.
The main switch of the
control system is not switched
On.
Bulb defective.
No mains voltage.
Fuse cut out.
Remedy
Check the FI-switch and the fuse in the mains
supply.
Adapt room temperature of the control
system >0 ºC or <25 ºC.
Do not operate the control system.
Inform Klafs Service.
Switch On the control system at the main
switch and turn the controller of the bathing
temperature all the way to the right.
Switch On the main switch at the control
system.
Change the bulb.
1.
Remove power from the control system.
2.
Replace with a bulb of the same
wattage.
Check the FI-switch and the fuse in the mains
supply.
Change the fuse.
1.
Remove power from the control system.
2.
Change the fuse (1.25 AT) or inform
Klafs Service.
PAGE 9

Publicidad

loading