Adjustment of the fixed knife:
The knives are adjusted by the manufacturer. So this instruction shall only be used after repairs.
1) Check that the screws (pos. 3) are tightened.
2) The screws (pos. 2) are turned till "handtight".
3) The screws (pos. 4) are tightend sufficiently so that the fixed knife (pos. 1) is just touching the
rotorblades. During tightening the rotor is turned manually and it must be checked that the
resistance against turning is equal for all rotorknives.
4) The screws (pos. 5) are tightend and the position of the knives is checked by feeding a thin piece of
paper down between the knives while the rotor is turned manually. It must be checked that each
rotorknife is cutting over its total length. The screws (pos. 2) are tightened and the check is
repeated. If the knives are not cutting evenly adjustment is made by means of screws (pos. 4 and
5).
5) The blower is turned off at the electric control unit and the Granulator is turned on. If the
Granulator is making noise the screws (pos. 4) are loosened and the screws (pos. 5) are tightened
until the noise stops. To avoid damaging the knives adjustment, while running, must be done with
extreme care and therefore the screws (pos. 2) must not be loosened.