EN
Replacing spare parts:
When spare parts are being replaced, it is recommended they are replaced by the manufacturer.
If this is not possible, these instructions should be followed:
1) The motor should be disconnected from the power supply.
2) When parts are being replaced inside the Granulator, the motor and Granulator should be separated
(see page 5) and the coupling and coupling carrier plate taken out with the motor.
3) The locking ring is first removed. The bearing housing, rotor, and bearings can then be removed
altogether.
4) When new bearings are to be fitted, pressure should be applied to the inner race to get the bearings into
position on the rotor. The bearing housing is then mounted so that rotor, bearings, and housing form a
single unit.
5) The unit is carefully put in place so that the bearings are not overloaded. The locking ring is then fixed in
position.
6) The Granulator and motor can now be assembled after it has been first checked that the coupling and
coupling carrier plate are properly seated.
The fixed blades should be replaced from outside (see page 6).
1) The blade can be taken out by removing the cover plate, adjustment plate, and screw holding the blade
in place.
2) Important! When any part of the machine whatever has been replaced, the fixed blade should be
adjusted according to the relevant instructions.
4
Manual_GR140_160123_EN