Adjustable wrench
Thank you for choosing the latest innovation in low power consumption EcoPower products.
Please note below the duration of time required to initialize the electronics.
It will take approximately 5 minutes after connecting the battery for the electronics to
initialize.
This delay is a normal part of startup.
After approximately 30 seconds, the sensor LED will start flashing in 4 second intervals
until the initialization is complete.
Fully Automatic and Hygienic
The EcoPower Flush Valve uses an infrared sensor to detect the user using and departing the
fixture, to provide an automatic flush of the fixture after 3 seconds. No manual operation is
required, improving the experience of use and hygiene of the fixture.
Courtesy Flush
When the fixture is not used for 24 hours the protection timer commands the system to flush in
order to maintain the trap seal.
Manual Functionality
For maintenance and emergency use, the EcoPower Flush Valve is equipped with a manual
flushing button.
Conserves Power
The flushing of the fixture activates a hydropower generator which generates electric power for
the next flush. (See About TOTO's Hydropower Generator, page 5)
Conserves Water
The EcoPower Flush Valve offers consecutive flush prevention to save water. After a flush, the
valve will not automatically flush again for 30 seconds.
TOTO EcoPower Flush Valve are designed to work for 10 years, under normal conditions,
with no minimum daily usage required.
COMMON TOOLS NEEDED
Screwdrivers (Phillips and Flat head)
INITIALIZING THE ECOPOWER PRODUCT
Green Features
FEATURES
- 3 -
Offset pipe wrench