Descargar Imprimir esta página

Toto TET1LB Manual De Instrucciones Y Del Propietario página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure
Model Number
Rated Flush Volume
Toilet
Control stop inlet
Flush Valve inlet
Flush Valve outlet
Min
Supply water
(Flowing)
pressure
Max*
(Static)
Shutoff pressure
Dimension of cover
Detection range
from the front
Detection time
Delayed flush
Trap seal protection
Ambient temperature
Water temperature
NOTE:
The type of fixture determines the minimum pressure required for the valve. Consult fixture
manufacturer for the pressure requirement. TET6LB, TET6GB and TET6UB require 24" OR
LONGER vacuum breakers. The valve will not have the proper detection range if you use a
shorter vacuum breaker.
* Water pressures over 80 psi are not recommended for most plumbing fixtures.
SPECIFICATIONS
TET1GB
TET6GB
1.6 G (6 L)
15 psi (103 kPa)
125 psi (862 kPa)
7-1/4" (H) x 4-9/16" (W) x 3-3/16" (D)
< 185 mm (H) x 116 mm (W) x 82 mm (D) >
- 4 -
Toilet
TET1LB
TET1LBX
TET6LB
1.28 G (4.8 L)
Flush Valve type bowl
1" NPT
1-1/4" NPSM
1-1/2" NPSM
25 psi (173 kPa)
125 psi (862 kPa)
7 psi (48 kPa)
Within 39-3/8" (1000 mm)
6 seconds
3 seconds
TET1UB
TET1UBX
TET6UB
1 G (3.8 L)

Publicidad

loading

Este manual también es adecuado para:

Tet1lbxTet6lbTet1ubTet1ubxTet6ubTet1gb ... Mostrar todo