Descargar Imprimir esta página

Hofmann monty 3300-24 smart Manual De Operador página 16

Publicidad

Standard models
1 Speed
115 V, 1Ph, 60Hz, 6A
1
6
7
16
All manuals and user guides at all-guides.com
2.5 Electrical connection
ATTENTION.: Any intervention on the electrical
system and the connection of a plug (when
necessary), must be performed only by a qualifi ed
electrician, in compliance with the applicable
standards and national laws and/or local
regulations.
The standard models of the tyre changers have
specifi c electrical specifi cations and are supplied
according to the different power supplies that they
will be connected to; See the table aside.
The electric motors operate with a voltage tolerance;
equal to more or less 10%.
The power supply cable, which is always provided
with the machine, must be fi tted with an adequately
sized type-approved plug, in compliance with the
applicable standards in the destination country.
single speed
For the installation technician
The qualifi ed electrician, when fi tting a plug, must
refer to the data clearly set out on the plate found on
the machine electrical cable.
The user must ensure that the electrical system that
the machine is connected to is fi tted with 10 A delayed
fuses or alternatively, an equivalent automatic
magneto-thermic switch.
Check that there is an effi cient earthing system.
Once the connection is complete, press the self-
centring rotation pedal downwards (1, Fig. 6) and
check that it rotates clockwise.
Check that the power supply system is fi tted with an
automatic cut off device against overcurrents, with a
differential calibrated to 30 mA.
2.6 Pneumatic connection
2.6 Pneumatic connection
The pressure in the compressed air network must not
The pressure in the compressed air network must not
exceed 232 PSI.
exceed 16 bar.
For pneumatic connection of the machine make sure
For pneumatic connection of the machine make sure
the jaws remain closed (risk of personal injury) and
the jaws remain closed (risk of personal injury) and
proceed as follows:
proceed as follows:
• Connect the supplied bayonet connector to the
• Connect the supplied bayonet connector to the
compressed air inlet.
compressed air inlet.
• At this connector, connect the tyre changer to a
• At this connector, connect the tyre changer to a
compressed air network (operating pressure 110 to
compressed air network (operating pressure 8 to 12
170 PSI) using a compressed air hose with an internal
bar) using a compressed air hose with an internal
diameter of 5/16" / 8 mm.
diameter of 8 mm / 5/16".
The tyre changer with Tubeless wheel System is
equipped with a pressure limiting valve.
Removing or tampering with this safety valve (pressure
limiter Fig. 7) is a violation of European Safety
Regulations and will relieve the manufacturer from
all liability.The compressed air outlet may only be
used to connect infl ating devices. If the machine is
connected to the compressed air network at this outlet,
the compressed air system and safety devices will be
destroyed.
For further details, consult the pneumatic diagram
shown in the spare parts list.