05.
Explana on produc on label
1.
Ar cle number VV
2.
Serial number
3.
Wiring diagram
4.
Voltage (V)
5.
Frequency (Hz)
6.
Nominal current (A)
7.
Rota on speed (RPM)
8.
Power (kW of PK)
9.
Cos phi
10. Service factor
11. Service factor ampere
12. Full load ampere
13. Capacitor (μF/V)
14. Max. ambient temperature C
15. Min. ambient temperature C
16. IE2
17. μ 100%
18. μ 75%
19. μ 50%
20. Thermal protec on (*)
21. Year of construc on
22. Bar code
23. Winding diagram
24. Weather proof
(*) Thermal protec on (NC) (for single phase: 250V 2.5A cosφ =1 / for 3-phase: 250V 10A cosφ =1)
06.
Assembly / Moun ng / Installa on
•
Moun ng, electric connec on and start-up may be executed by qualifi ed personnel only (according to EN 50110-1
and EN 1010-1).
•
It is the installer's responsibility that the installa on and safety instruc ons are in accordance with current
standards and regula ons (according to EN-ISO 13857 and EN ISO 12100-1)
•
Every fan has to be grounded according to the current standard EN 50178.
•
Do not use the fan as part of a construc on
•
In case the moving part of the fan (the impeller) is below 2.7 m (measured from the fl oor to the lowest point of
the fan), a protec ve wire guard (according to EN-ISO 13857) is mandatory.
•
Remove the red condense plug, mounted at the lowest point of the motor. Keep the condense plug in a safe place,
for it is necessary to use it during cleaning and maintenance work.
•
Keep the water outlets open at all mes.
•
Always install the fan with the motor in the le or right top corner to avoid clogging.
•
Do not anchor the fan with cement or expanding building or sealing foam in its moun ng posi on.
•
Using the op onal fastening set is recommended.
•
Always a ach the cover on the hub. This avoids humidity penetra ng the bearings, causing a serious reduc on of
the life span.
CAUTION: In case of speed regula on, the fan may vibrate when incorrectly mounted/installed.
Check this before comple ng the installa on.
CAUTION: The fan must ALWAYS be built-in or mounted in a stable way before being taken into
opera on!
VF9375C (02/2017)
Transla on of the original manual
25. Drip proof
26. IP class
27. Insula on class
28. TEAO (Totally Enclosed Air Over)
29. Number of phases
30. Manufacturers name
31. Manufacturers address
32. Manufacturers country
33. cURrus logo
34. CE-logo
35. CSA-logo
36. W333 bin
37. Tester code
38. Work order date
39. Fan type
40. Imax (A)
41. P
e
42. VSD used
43. Part number customer
44. Weight (kg)
45. Controllability
46. Energy effi ciency category
47. Energy effi ciency sta c or total
48. μ Overall
49. μ at optimum
50. Sta c pressure (0 Pa)
3
51. Air volume at 0Pa (m
/h)
52. Sta c pressure (x Pa)
3
53. Air volume at x Pa (m
/h)
54. PSE-logo
55. Fan current (A)
56. Pressure at 0 inwg.
57. Air volume at 0 inwg.CFM
58. Pressure at -x- inwg.
59. Air volume at -x-inwg.CFM
60. Max. ambient temperature F
61. Min. ambient temperature F
62. Order
63. Not used
64. Motor data. For.....
65. House code
66. Acceptable for fi eld wiring
67. Min
-1
applica on
68. Cos phi applica on
69. Wiring diagram applica on
70. QR code
71. Rotor code
72. EAC logo