Descargar Imprimir esta página

Federal Signal G-SND Manual Del Usuario página 8

Generador de sonido

Publicidad

Idiomas disponibles

Idiomas disponibles

For 24 Vdc operation (remote switching of tones with remote power)
a.
Set the tone selector switch to 0.
b.
Connect the negative (–) power source wire to the terminal block position marked L2 on the PCB.
c.
Connect the positive (+) power source/select wires to the terminal block positions marked T1, T2, T3, and
T4.
d.
Connect the ground wire to the terminal block position marked EARTH.
6.
Insert the PCB into the enclosure and fully tighten the PCB captive screw.
7.
Place the cover on the housing and tighten it by turning it clockwise.
8.
To ensure O-ring compression, the cover must be fully seated against the housing when the threads are tightened.
Turn the M3 set screw on the side of the housing until the screw contacts the housing.
9.
Ensure that the unused wire entry is sealed with the provided brass M20-1.5 x 6 g stopping plug (equipment-
certified).
8
Tone
Description
(Position)
0 (0)
Off
1 (1)
Two Tone
2 (2)
Sleeping Quarters EVAC
3 (3)
Warble
4 (4)
Constant
5 (5)
Simulated Bell
6 (6)
Swept 1
7 (7)
Two Tone
8 (8)
700 Hz
9 (9)
Swept
10 (A)
Swept
11 (B)
1 KHz
*12 (C)
Constant 1 kHz
13 (D)
Two Tone
14 (E)
Warble
15 (F)
Swept
*Factory setting
Table 1 Tone chart
Frequency
588 Hz
714 Hz
520 Hz
1000 Hz/1400 Hz
Silence
Warble
Silence
700 Hz 700 Hz
~ 3 rings per s
.6 kHz to 1.2 kHz
1.2 kHz to 2.6 kHz
1 kHz
700 Hz
700 Hz
Silence
400 Hz to 1.6 Hz
Constant 1.2 kHz
1.2 kHz to 400 kHz
Silence
550 Hz to 735 Hz
1 KHz
Silence
1 kHz
700 Hz
500 Hz
1 kHz to 1.4 kHz
1.2 kHz 400 Hz
Duration
0.25 s
0.25 s
Three 0.5 s ON
Three 0.5 s OFF
1.5 s pause
4 s cycle
0.4 s
0.25 s
0.4 s
0.2 s
6 cycles per s
0.4 s
0.4 s
0.25 s
0.25 s
1 s
2 s
1 s
5 s
0.5 s
1 s
1 s
0.5 s
0.5 s
10 cycles per s
1 s
Federal Signal signaling.fedsig.com

Publicidad

loading