NOTE
A suitable power supply must be available at the installation location.
1. Remove the packing film, the tensioning straps and the wooden boards
from the individual packing units.
2. Remove both clamping rings (item 4) from the fan unit (item 1), lift off
the intake unit (item 3) and place it next to the fan unit.
3. With suitable carrying tackle that is mounted in the interior of the fan
unit, lift the fan unit from the pallet and set down at the installation
location.
4. Remove the start-up protection by loosening the screws all round. Then
it can be taken off outwards.
5. In the floor plate of the fan unit, there are eight fastening holes to
anchor the product securely to the hall floor. Suitable fixing material
must be used for anchoring it.
We recommend the following fixing material for reinforced concrete
C25/30:
1502778-02
Fig. 30: Assembling the fan unit