3. Attach a suitable carrying harness to the eyebolts (item 6) in the upper
part of the main filter (item 5) and connect it to a lifting device such as a
forklift or crane.
4. Detach the main filter (item 5) from the fan unit (item 7) by removing
the lower clamping ring (item 3).
5. Now carefully lift the contaminated main filter (item 5) off the fan unit
(item 7) using the lifting device and dispose of it in accordance with the
applicable regulations.
6. Lift the new main filter unit (item 5) by the eyebolts and place it on the
fan unit (item 7) and connect it to the clamping ring (item 3). Please
ensure the proper fit of the seal in the clamping ring (Pos. 3).
7. Place the pre-filter unit (item 4) on the main filter and fix it in place with
the clamping ring (item 3).
8. Connect the product to the power supply and press the on/off switch to
put it back into operation. See also the chapter Commissioning.
1502778-02
Fig. 47: Replacement of the main filter
- 94 -