VIII. - FORCED CONVECTION. (Mod. H03 TURBOCONVECTOR)
A. - Installation
Ventilator
Install the ventilator in the preferred position (see fig. 22 Page. 22) using the screws
provided, if position 2 or 3 is chosen remove the top and place it together with the fibre
joint in the window of position 1. Connect the two loose white cables to the contact
thermostat located on the side of the
wood burner. Afterwards connect the
circuit to the electric network.
Check that it works correctly by placing
the switch of the power regulator in the
ON position with the potentiometer at
minimum. The ventilator should turn
slowly.
Check that the regulator is working by
slowly turning it up to maximum. Now the
ventilator
will
gradually
turning speed up to the maximum speed.
Chimney
Connect the H03 TURBO-CONVECTOR
Wood Burner to the chimney following the
instructions contained in chapter II.
Forced convection
The air outlets from the convection
chamber must be connected using flexible
tubes to the areas where you wish to
direct this flow, either to the room where
the wood burner is installed or to other adjacent rooms.
The H03 TURBOCONVECTOR wood burner will be supplied with half of the outlets closed
with caps (see fig. 22). This can be used according to the number of outlets that you need.
Never leave an outlet open inside the casing, as convection efficiency will be lost.
It is essential that the casing which is used to surround you H03 TURBOCONVECTOR
wood burner has a removable panel so as to be able to access the ventilator and its
connections in the future if necessary.
The chamber where the H03 TURBOCONVECTOR wood burner is installed must have an
air inlet in its lower section which is sufficient for supplying the ventilator. Is it advisable
that the air inlet of the ventilator is carried out if possible from outside the house or failing
that from another room separate to the one where the wood burner is installed. The grate
will have a minimum free flow section of 400 cm
prevent depressions within the chamber which could suck in smoke from the wood burner.
It is necessary to place a grate on the upper section of the casing to dissipate the heat
from this chamber so as to prevent cracks being produced in the casing due to
accumulated excess heat.
The optimum form of air distribution is to place commercial adjustable grates on the outlets
to the various rooms, in such a way that you can choose at any time to which places you
want to direct the flow of hot air.
increase
its
40
Air outlet to
other rooms
Air outlet to
other rooms
Air outlet
to the room
Air inlet for
THe fan.
Fig.-16 – Guide Diagram
orientativo
2
, which will not be able to be closed, to
Air outlet to
the room
Natural lining
convection outlet
Chimney
conduit