3 . Ensure that the wire ends/leads are not
bent or frayed, as this will prevent proper
installation. Begin by installing the double-
ended lamp within the lamp holders shown
in PHOTO A .
4 . The wire ends/leads must be fully seated
as shown (PHOTO B) before sliding each
socket end closed .
5 . After sliding the socket ends closed, be
certain that there is no gap between the
edge of the sliding section and the part it
meets at the end of the slide path. Once
lamp is positioned correctly, slide the lamp
holder inward toward the center of the
lamp to secure and lock the lamp in place
as shown in PHOTO C.
WARNING – POSSIBLE RISK OF INJURY TO EYES AND SKIN
• Hazardous optical radiation may be emitted from the light source. Do not stare at operating
lamp. May be harmful to the eyes.
• UV may be emitted from the light source. Eye or skin irritation may result from exposure.
Use appropriate shielding.
• IR may be emitted from the light source. Do not stare at operating lamp.
WARNING – WHEN USING METAL HALIDE DOUBLE ENDED LAMPS, 1000W
(100%) OPERATION ONLY.
WITH DOUBLE JACKET.
WARNING: FAILURE TO FOLLOW GUIDELINES COULD RESULT IN ELECTRICAL SHOCK.
Do not touch, move, spray, or clean your light fixture when it is plugged in. Allow it to cool down before
handling. Recommended mounting clearance for your fixture is 8"–12" on all sides. Do not mount
directly to any surface. Make sure to disconnect the power when changing the lamp.
INSTALLING THE LAMP, continued
DO NOT DIM/BOOST! USE ONLY OPEN RATED LAMPS