PHANTOM 60 SERIES BALLAST ELECTRICAL SPECIFICATIONS
Main
Model
Watts
Voltage
PHB6015 1000W 208–240V 185–265V 1236W
PHB6024 1000W 277–400V 249-440V 1236W
PHB6030 1000W
480V
Model
Irated 208/240V
PHB6015
6.1A/5.3A
Irated 277/400V
PHB6024
4.8A/3.3A
Irated 480V
PHB6030
2.8A
• Microprocessor Control
• LED Status Indicator
• Open Circuit Protection
• Open Circuit Indicator
• Short Circuit Protection
• Short Circuit Indicator
• Overtemperature Protection
• Overtemperature Indicator
• End-of-Lamp-Life Sensor
• End-of-Lamp-Life Indicator
ELECTRICAL SPECIFICATIONS
Operating
Max
Voltage
Input
Output Power Settings
Range
Power
600W-660W-750W-825W-
1000W-1150W
600W-660W-750W-825W-
1000W-1150W
432-528V 1226W
600W-660W-750W-825W-
1000W-1150W
BALLAST INPUT AMPERAGE REFERENCE
1150W 208/240V
1000W 208/240V
6.1A/5.3A
5.4A/4.7A
1150W 277/400V
1000W 277/400V
4.8A/3.3A
4.1A/2.8A
1150W 480V
1000W 480V
2.8A
2.4A
PHANTOM 60 SERIES BALLAST FEATURES
Power
Ignitor
Factor
Voltage
> 0.97
3–5 kV
> 0.97
3–5 kV
> 0.97
3–5 kV
750W 208/240V
825W 208/240V
4.5A/3.9A
4.1A/3.6A
825W 277/400V
750W 277/400V
3.4A/2.4A
3.1A/2.2A
825W 480V
750W 480V
2.0A
1.8A
• Over/Undervoltage Protection
• Over/Undervoltage Indicator
• Patented Ignition Control
• RJ12 Port to Integrate with PX Lighting
Controller
• Auto-restrike Protection
• Internal EMI Suppression
• 18/3 AWG Power Cord
• Vent Plug
7
THD
CF
ta
< 8% 1.414–1.6 40°C/104°F 80°C/176°F
< 8% 1.414–1.6 40°C/104°F 80°C/176°F
< 8% 1.414–1.6 40°C/104°F 80°C/176°F
660W 208/240V
600W 208/240V
3.7A/3.2A
3.3A/2.9A
660W 277/400V
600W 277/400V
2.8A/2.0A
2.5A/1.8A
660W 480V
600W 480V
1.6A
tc
1.5A