WARM UP
PLEASE WAIT 120
Wait for the extruder to warm up.
Note
The extruder is equipped with a safety system that disables the motor if:
•
the minimum working temperature has not been reached;
•
a new set point, that is greater or lower than 10°C, has been typed in.
Once the heating time has been elapsed (READY!), the blower turns on and
the air flows from the front hose at the set point temperature.
278
The temperature of the air and the extrudate chamber are those stored
since the last usage.
AIR TEMPERATURE SETTING
Hold button 2 pressed for 3 sec. Use buttons 2 and 3 to set the air
temperature within the range T min=250°C – T max=365°C. The new setting
point is stored after 5 sec.
2
3
16
EN
HEATING
READY!
215
CHANGE
280
EXTRUDATE TEMPERATURE SETTING
Hold button 7 pressed for 3 sec. Use buttons 6 and 7 to set the air
temperature within the range T min=195°C – T max=260°C. The new setting
point is stored after 5 sec.
7
6
Working temperature
Please refer to standard DVS 2207-4.
CHECKS
Make sure the extrudate-hose is not clogged before triggering the motor.
If necessary, gently remove the extrudate clogging when it's turning soft
with a flat screwdriver tip.
WARNING! Use eyewear. Do not stand in front of the
extrudate hose.
P
B
Pull the motor trigger P and button B to start the extruder.
CHANGE
220