Descargar Imprimir esta página

SICK W4F Instrucciones De Uso página 22

Ocultar thumbs Ver también para W4F:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
4
MOUNTING
4
Mounting
en
5
Electrical installation
22
O P E R A T I N G I N S T R U C T I O N S | WSE4F
BluePilot blue: alignment aid
1
Teach-Button: adjusting the sensitivity
2
Yellow LED: status of received light beam
3
Green LED: supply voltage active
4
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK
range of accessories). Align the sender and receiver with each other.
NOTE
When mounting multiple through-beam photoelectric sensors next each other, swap
the arrangement of the sender (WSO4F) and receiver (WEO4F) for every second pair.
Also maintain a sufficiently large distance between the pairs based on the light spot
diameter of the sender (WSO4F). See
Sender (WS)
Receiver (WE)
Sender (WS)
Figure 12: Arrangement of multiple through-beam photoelectric sensors
Dimensions in mm (inch)
200
(7.87)
100
(3.94)
0
–100
(–3.94)
–200
0
2
4
(–7.87)
(6.56)
(13.12)
(19.69)
Recommended sensing range for the best
performance
Figure 13: Light beam diameter
Note the sensor's maximum permissible tightening torque of < 0,4 Nm.
Operation in standard I/O mode:
figure 12
and
figure
6
8
10
(26.25)
(32.81)
1
Distance in m (feet)
(3.28)
13.
Receiver (WE)
Sender (WS)
Receiver (WE)
10
(32.81)
8025304.1DTW /2022-02-14 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para:

Wse4f