Descargar Imprimir esta página

King Innovation KING 95 Manual De Instrucciones página 2

Publicidad

TABLE OF CONTENTS
1. SAFETY INFORMATION ........................................ 3
2. GENERAL SPECIFICATION ................................... 4
3. ELECTRICAL SPECIFICATION ............................... 5
3-1 ACmA Measurement ............................................. 5
3-2 ACA Measurement ................................................ 5
3-3 ACV Measurement ................................................ 6
3-4 DCV Measurement ................................................ 6
3-5 Continuity (
) ..................................................... 6
3-6 Resistance (Ω) ........................................................ 6
4. DESCRIPTION .............................................................. 7
4-1 Description of the display ..................................... 7
4-2 Description of front and rear ................................ 8
5. BUTTON INSTRUCTION ........................................ 9
5-1 HOLD & LPF Function ............................................ 9
5-2 PEAK HOLD Function ............................................ 9
5-3 ZERO Function ....................................................... 9
5-4 BACKLIGHT Function ............................................ 10
6. MEASURING INSTRUCTION .............................. 10
6-1 ACA & ACmA Measurement ................................ 10
6-2 ACV Measurement ................................................ 12
6-3 DCV Measurement ................................................ 13
6-4 Continuity Measurement ....................................... 13
6-5 Resistance Measurement ...................................... 14
7. CHANGING THE BATTERY ................................... 14,15
8. MAINTENANCE .......................................................... 15
8-1 Cleaning ................................................................. 15
I
2
KING INNOVATION
MILLIAMP CLAMP METER
1.
SAFETY INFORMATION
• Do not operate the tester if there is any sign of damage
to the tester or the test leads.
• Check the main function dial and make sure it is in the
correct position before each measurement.
• Do not perform resistance and continuity test on a live
power system.
• Do not apply voltage between the test terminals and test
terminal to ground that exceed the maximum limits stated
in this manual.
• Keep your fingers behind the protection ring on the test
probes when using the test leads.
• Change the battery when the
avoid incorrect data.
Environmental Conditions
Operation Temperature: 0°C to 40°C (32°F to 104°F);
<80 % RH
Storage Temperature: -10°C to 60°C (14°F to 140°F);
<80 % RH
Altitude: Up to 2000 meters
Pollution Degree: 2
Explanation of Symbols
Attention refer to operation instructions.
Approvals
CONFORMS TO UL STD. 61010-1,
CERTIFIED TO CSA STD. C22.2 #61010-1-12,
3131884
symbol appears to
61010-2-032, 61010-2-033
61010-2-032, 61010-2-033
I
KING INNOVATION
3

Publicidad

loading

Este manual también es adecuado para:

42095