INSTRUCTION MANUAL
2. GENERAL SPECIFICATION
The King Innovation KING 95 Digital Milliamp Clamp Meter is
ideal for use in troubleshooting two-wire irrigation, landscape
lighting and electrical systems. The KING 95 is for use in
indoor and outdoor dry locations.
Digital Display:
4 digit liquid crystal (LCD) maximum reading 6000
Polarity:
When a negative signal is applied, the "
Low Battery Indication:
When the battery voltage is below that required for proper
operation when the
symbol will appear on the LCD
display.
Sample Rate:
2 times/sec for digital data.
Power Source:
1.5 size AAA battery X 2
Typical battery life: (without buzzer, backlight)
40 hours at ACmA and ACA function;
60 hours at DCV and Ohm function. (alkaline battery)
Auto Power Off:
If a key is not pressed or dial operated for 30 minutes, the
meter will power itself off to save battery life. This function can
be disabled by pressing and holding the "HOLD" button and
powering on the unit.
Over Load:
When the applied signal is larger than the maximum for the
range in use the display will show
Maximum Jaw Opening:
.79" (20mm)
Dimensions:
8.27" x 2.87" x 1.50" (210 x 73 x 38mm)
Accessories:
Carrying case, batteries, test leads and instruction manual.
I
4
KING INNOVATION
" signal appears.
OL
.
MILLIAMP CLAMP METER
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± (percent of reading
+ digit) at 23±5°C, ≤ 80 %RH.
Safety Class - CAT III 600V
3-1 ACmA (True RMS)
Range
Resolution
6.000mA
0.001mA (1μA)
60.00mA
0.01mA (10μA)
600.0mA
0.1mA (100μA)
Zero correction: Fractions smaller than approximately 0.006
mA are calibrated to zero.
Low Pass Filter
Range
Resolution
6.000mA
0.001mA
60.00mA
0.01mA
600.0mA
0.1mA
3-2 ACA (True RMS)
Range
Resolution
6.000A
0.001A
60.00A
0.01A
Low Pass Filter
Range
Resolution
6.000A
0.001A
60.00A
0.01A
Accuracy
50 ~ 60Hz
60 ~ 500Hz
1.0% + 8dgts
2.0% + 8dgts
1.0% + 5dgts
2.0% + 5dgts
Accuracy
2.0% + 8dgts
2.0% + 5dgts
Accuracy
50 ~ 60Hz
60 ~ 500Hz
1.0% + 5dgts
2.0% + 5dgts
Accuracy
2.0% + 5dgts
I
KING INNOVATION
5