CARE & MAINTENANCE
CLEANING
1
Separate all parts.
2
Wash all cups in warm, soapy water with
a soft cloth.
3
Hand-Washing
Wash containers, lids, blade assemblies,
and overflow reservoir in warm soapy
water. Use a dishwashing utensil with
handle to avoid direct contact with the
blades. Exercise care when handling the
blade assembly as the blades are sharp.
Thoroughly rinse and air-dry all parts.
TIP: If you find residue underneath
the FreshVac™ Tab, try lifting it gently
and rinsing under warm water. DO NOT
remove FreshVac Tab.
Dishwasher
Containers, lids, and blade assemblies are
dishwasher safe. Place the containers, lids,
and blade assemblies on the top rack of
the dishwasher ONLY. Ensure the blade
assemblies and lids are removed from the
container before placing in the dishwasher.
Make sure Flip & Seal Lid on the cup is
open before starting cleaning cycle.
NOTE: Overflow reservoir is not
dishwasher safe.
Motor Base
Turn off the unit and unplug the motor base
before cleaning. Wipe motor base with a
clean, damp cloth.
FreshVac™ Pump
NEVER submerge the pump in water or other
liquid. If you see water or other liquid in the
overflow reservoir:
1 Remove overflow reservoir from pump
and wash and dry it thoroughly.
2 Run pump for 10 seconds to clear
any fluid.
3 Wipe pump clean with a soft cloth.
4 Reattach overflow reservoir to pump.
28
STORING
Wrap power cord around cord wrap on back
of motor base. Store unit upright and store all
blade assemblies inside or attached to their
respective containers with their lids locked
into place.
DO NOT store blended or unblended
ingredients in the Single-Serve FreshVac Cup
with the Pro Extractor Blades® Assembly
attached. Use only the spout lid when storing
blended or unblended ingredients in the cup.
DO NOT stack items on top of the cups.
Store any remaining attachments alongside
the unit or in a cabinet where they will not be
damaged or create a hazard.
RESETTING THE MOTOR THERMOSTAT
This unit features a unique safety system
that prevents damage to the motor and
drive system should you inadvertently
overload it. If the unit is overloaded, the
motor will be temporarily disabled. Should
this occur, follow the reset procedure below.
1
Unplug the unit from the electrical outlet.
2
Allow the unit to cool for approximately
15 minutes.
3
Remove the cup's blade assembly. Empty
the cup and ensure no ingredients are
jamming the blade assembly.
IMPORTANT: Ensure that maximum
capacities are not exceeded. This is the
most typical cause of appliance overload.
If your unit needs servicing, please call
Customer Service at 1-877-646-5288.
TROUBLESHOOTING GUIDE
WARNING: To reduce the risk of shock and unintended operation,
turn power off and unplug unit before troubleshooting�
Unit doesn't turn on�
• Make sure unit is plugged in.
• Display will read "
" once connected to power.
• Place container on base and rotate it clockwise until it clicks into place. Available
programs will illuminate, indicating the unit is ready for use.
Unit doesn't turn off�
• Remove container from base by rotating it counterclockwise and lifting it. Display
should turn off. Unplug the power cord from the outlet.
Container does not reach a full vacuum seal�
• FreshTab™ Tab is wet. Be sure all vacuum components are dry before using.
• Low battery. If your FreshVac Pump is taking longer than usual to pull a vacuum, try
replacing the batteries.
• Overflow reservoir is incorrectly assembled. Before operating the pump, be sure the
overflow reservoir is correctly assembled on bottom of the pump. Overflow reservoir
should sit flush to pump.
FreshVac Pump won't turn on�
• Ensure that working batteries are installed correctly in the pump and the battery cover
is securely in place.
• If using an optional AC adapter, make sure it is manufactured by SharkNinja. Other
after-market adapters are not compatible with the pump.
• If using a SharkNinja AC adapter, make sure the connector is inserted fully into the pump.
FreshVac Pump won't turn off when using the pitcher�
The pump will shut off automatically once a vacuum seal is achieved. If a vacuum seal is
not achieved, you will be able to remove the pump from the lid. If this happens, turn off
the pump and check the following:
• Make sure the Pro Extractor Blades® Assembly is tightly attached to the cup.
• Ensure the FreshVac Tab on the Flip & Seal Lid is properly installed.
DO NOT remove the tab from the lid.
Accidentally removed the FreshVac tab and need to reinstall�
• In a case you accidentally remove the FreshVac Tab and need to reinstall, follow these
easy steps. First ensure the FreshVac Tab matches up with the opening on the Flip &
Seal Lid. Next, align the bottom side of the tab to match the shape of the opening on
the cup. Then press the tab down until it is seated flat.
What do the lights on the FreshVac Pump mean?
• White LED light indicates the pump has been activated and vacuum sealing
is in progress.
• Green LED light indicates vacuum sealing is complete. Pump will automatically
shut off when complete.
• A blinking white and green light indicates the batteries have been loaded incorrectly
or need to be replaced.
Can't remove Pro Extractor Blades® Assembly from cup or lid from pitcher�
• Container will be vacuum sealed shut after using the FreshVac Pump.
• Release the vacuum seal by gently pulling up on the FreshVac Tab.
FreshVac Pump does not lock onto container�
• Pump will not lock onto pitcher lid or cup. Once pump is activated, the pump will seal
to the lid and become secure.