Ventilation
The refrigeration unit is ventilated only via
the ventilation grille in the base. Never cover
the ventilation grille or place anything in front of it.
Otherwise the refrigeration unit must work harder,
increasing the power consumption.
Connecting the appliance
Have a technician install and connect the appliance
according to the enclosed installation instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until
the appliance has been installed.
In addition to the statutory national regulations,
observe the connection conditions of the local power
supply companies.
After installing the appliance, wait at least 1 hour until
the appliance starts up. During transportation the oil
in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
"Cleaning the appliance").
6
Electrical connection
9
WARNING:
Risk of electric shock:: Connect the appliance to a
grounded, 3-phase outlet only. Never remove the
ground phase. Do not use any adapters.Do not use
any extension leads.
9
WARNING:
Risk of electric shock:: Incorrect connection of the
appliance may result in death, fire or electric shock.
Improper connection of the protective conductor may
result in electric shock. If you are in doubt as to
whether the appliance has been properly grounded,
have it tested by a qualified electrician or Customer
Service technician.
9
WARNING:
Risk of electric shock:: If the length of the power cord
is inadequate, never use multiple outlets or extension
leads. Instead, please contact Customer Service for
alternatives.
This appliance must be connected to a permanently
installed outlet.
The outlet must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect it to a correctly installed outlet. Correct
means: with a protective conductor, 110 V – 120 V/
60 Hz alternating current. The outlet must be
protected by a 10 A – 16 A fuse.
The appliance comes with a UL registered 3-wire
power cord. The appliance requires a 3-pole outlet.
Please observe the following table with regard to this:
Appliance
Maximum simultaneous load
Wine refriger-
2 A
ator
Check on the rating plate whether the indicated
voltage and current type match the values of your
power supply. The position of the rating plate can be
found in the chapter entitled Customer Service.
9
WARNING:
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are
used for photovoltaic systems which are connected
directly to the national grid. Sine-controlled inverters
must be used for isolated applications (e.g. on ships
or in mountain lodges) which are not connected
directly to the national grid.