8) ELECTRIC CONNECTIONS
The cables necessary for the installation of BOB can vary according to the accessories installed.
No connection cable is supplied.
Fig. 6 indicates the cables for standard installation.
List of cables
Connection
A
Mains power supply to the control unit
B
Motor connection
C
Photocell transmitter connection
D
Photocell receiver connection
E
Key selector connection for external command
F
Flashing signal light connection
G
Connection of the aerial built-in the flashing light
Legenda
1
Motoreducer
2
Photo-electric cells
3
Key selector (external) or digital keyboard
4
Flash-light
5
Electronic board
The cables used must be suitable for the type of connection. For example, for connection protected by raceways use
H03VV-F cables, for cables in the outdoor environment always use the H07RN-F type.
TECHNICAL DATA
Power supply
Absorbed rating
Absorbed current
Thrust
Jogging
Protection degree
Operating temperature
Door leaf max. weight
Useful stroke:
- with 2 mechanical stoppers
- with 1 mechanical stopper
- without mechanical stoppers
Translation speed
Noise level
Lubrication
Weight
Type
3x1,5mm
2
4x1,5mm
(3x0,5mm
BOB 30ME)
2
2
2x1,0mm
2
4x1,0mm
2
2x1,0mm
2
2x1,5mm
2
RG 58
BOB5024/BOB5024E
24Vdc
120 W
6,7 A
2200 N
intensive
IP44
-20°C / +50°C
500 kg
455 mm
485 mm
520 mm
0,8 m/min
<70 dB
Permanent grease
11,6 kg
13