Danger
Risk of injury! The main switch is to be switched off while carrying out any repairs or maintenance jobs.
Time
Activity
daily
Check hand-
spray gun
Check high pres-
sure hoses
weekly or after
Check oil level
40 operating
Check oil level
hours
Cleaning the
sieve
monthly or after
Check pump
200 operating
hours
Check for inter-
nal deposits
Cleaning the
sieve
after 500 - 700
Replace
operating hours
half-yearly or af-
Oil change
ter 1000 operat-
ing hours
check, clean
Replace the
hose
annual
Safety check
Maintenance and care
Maintenance schedule
Assembly affected
Hand spraygun
Outlets, hoses towards working
machine
Oil tank at the pump
Oil tank at the pump
Sieve in water inlet
High-pressure pump
Entire plant
Sieve in the water shortage
safe guard
Electric igniter, ionisation elec-
trode
High-pressure pump
Entire plant
Hose to exhaust pushbutton
switch
Entire plant
Performance
Check whether the hand-spray gun closes tightly
without any leaks. Check the protection mecha-
nism against accidental switching. Replace de-
fective hand-spray guns.
Check hoses to see if there are damages. Re-
place defect hoses immediately. Danger of acci-
dent!
If the oil is milky, it needs to be replaced.
Check oil level of the pump. Refill oil if required
(Order no. 6.288-016)
See section "Clean sieve".
Check the pump for leaks. If the leakage is more
than 3 drops per minute, call Customer Service.
Operate the machine using the spray pipe with-
out the high pressure nozzle. If the operating
pressure on the manometer of the machine in-
creases to more than 3 MPa, then the plant
needs to be decalcified. The same is applicable
when an operating pressure of more than 0.7 - 1
MPa is detected while operating the machine
without high pressure pipe (water comes out
freely at the high pressure outlet).
See section "Clean sieve".
Replace electric igniter and/or the ionisation
electrode.
Drain off oil. Fill in 1 l new oil (Order no. 6.288-
016). Check oil level in the oil tank.
Visual inspection of the plant, check high pres-
sure connections to see that they are not leaking,
check that the over-flow valves are not leaking,
check high pressure hoses, check pressure
tanks, remove calcium deposits from the heating
coil, clean/ replace ionisation electrodes, adjust
burner.
Install new hose.
Safety check according to the guidelines for fluid
spraying equipment.
of whom
Operator
Operator
Operator
Operator
Operator
Operator
Operator
trained in de-
calcification
Operator
Customer
Service
Operator
Customer
Service
Customer
Service
Technical
expert
31
English