Descargar Imprimir esta página

Taski ULTIMAXX 1900 Manual De Instrucciones página 114

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 124
Electronic brush lowering unit (touchscreen
only)
Notice:
The Power User (gray) key is required to set the
brush pressure with the electronic brush lowering
unit. (See page 110)
• Switch the machine on.
• Select the settings (gear symbol) in
the bottom right corner of the display.
Squeegee Assembly
• Position the suction nozzle [A2] be-
low the suction nozzle holder [A1].
• Press the foot pedal [1] down until
B
1
the suction nozzle holder engages.
1
1
A
A
• Attach the suction hose [B1] to the
1
connector [B2].
A
2
A
2
B
2
Filling the fresh water tank
Caution:
Max. permissible water temperature 60 °C/140 °F.
- Diversey recommends using cold water, as hot water
will adjust to the ground temperature as soon as it
comes into contact with the ground. Thus there are no
advantages to using hot water.
• The machine must be switched off.
• Put your hand into the opening be-
tween tank cover and tank and pull
A
the unlocking grip [A].
• Open the tank cover.
B
1
• Swivel the folding stand [B2] out of
the holder [B1] and place it into the
tank recess [C].
2
B
C
• Remove the dosage cup [D] and the
fresh water filter [E]
E
D
112
• Fill the fresh water tank with water.
Maximum filling level (page 105).
• Swivel the folding stand into the holder, tip the tank cover
back into its original position and press it down until it locks.
Fill fresh water tank with Aquastop filter (optional)
• Connect a water hose to the Aquas-
top filter.
• Fill the fresh water tank with water.
Dosing:
Warning:
Wear gloves, goggles and appropriate (protective)
working clothes when handling chemical products!
Danger:
Use chemical products recommended by Diversey
only and always observe the product information.
Using unsuitable products (e.g. products containing
chlorine, acids or solvents) may cause harm to health
and severe damage to the machine.
Notice:
For a precise dosing, use the scale in the dosing
cup.
- The filling level mark on the tank corresponds to the
mark in the dosing cup. The type of machine is also
noted in the dosing cup!
Information on
Tank capacity
the package of
the product
0.5%
1/2
MAX
1%
1/2
MAX
Dosage cup application
• Fill the product you have measured
with the dosage cup into the fresh
water tank.
• Slightly lift the tank cover.
• Swivel the folding stand back into the holder.
• Close the tank cover.
• By pushing gently on the front part of the tank cover you
lock the tank.
Automatic dosing (optional)
Notice:
TASKI offers an automatic dosing (IntelliDose) fea-
ture as an option. It is possible to mount it addition-
ally.
- Please contact your customer service.
Dosage cup
1 x 1/2
1 x MAX
1 x MAX (2 x 1/2)
2 x MAX