Protection type
IP 20
Connection cable
0,2 ... 1,5 m²
(cross section)
Wire stripping
8 ... 9 mm
length of connec-
tion terminals
4 Installation
Installing the device
See Fig. 3 [& 3]
Connecting the device
See Fig. 4 [& 4]
Close cover
See Fig. 5 [& 4]
5 Commissioning
First Open function
See Fig. 6 [& 5]
1. Establish the power supply to the base station.
2. All heating zones are activated one after the other for
ten minutes each to unlock the first-open function of
the connected actuators.
Coupling devices - Pairing
See Fig. 7 [& 5]
1a) Teaching room control units to heating
zones
ü Press and hold: <3 sec
ü Press briefly: <1 sec
1. Press and hold the button Pairing [B] to activate pairing
mode: The LED Pairing flashes slowly
ð The LEDs of all already coupled heating zones light
up permanently
ð The LEDs of all heating zones available for pairing
flash slowly
2. Press the button Pairing [B] briefly to select pairing for
the desired heating zone
ð The LED of the selected heating zone flashes quickly
3. Press the button Clear [A] briefly to confirm the previ-
ously selected heating zone for the pairing process: The
LED of the selected heating zone lights up permanently
ð To assign additional heating zones: Repeat steps 2
and 3.
4. Press and hold the button Pairing [B] to start the pairing
IP 20
0,2 ... 1,5 m²
5. Briefly press the rotary pushbutton of the room control
8 ... 9 mm
6. Press the button Pairing [B] on the base station briefly to
7. Briefly press the rotary pushbutton of the room control
1b) Teaching a room control unit to
additional heating zones
Perform the following steps to pair an already paired room
control unit with additional heating zones.
Start the pairing process on the base station and select the
desired heating zone(s), see 1a), steps 1 to 4.
1. Press and hold the push-turn control of the desired
2. Briefly press the rotary pushbutton of the room control
3. Press the button Pairing [B] on the base station briefly to
4. Briefly press the rotary pushbutton of the room control
Alpha Smart App
6 Decommissioning
Resetting the factory settings
See Fig. 8 [& 6]
1. Press and hold the buttons Clear [A] and Pairing [B] si-
2. Press the buttons Clear [A] and Pairing Press [B] simulta-
– The Power/ERROR LED flashes red quickly
– The reset process starts: All LEDs are controlled simulta-
process for the previously selected heating zones: The
LED Pairing flashes quickly
unit: PAI Join is visible in the display
complete the process: PAI done is visible in the display
unit to end the pairing process
room control unit: Set PAIr is visible in the display
unit: PAI Join is visible in the display
complete the process: Pai done is visible in the display.
unit to end the pairing process
In order to use the device within an Alpha
Smart Cloud, it is necessary to use the Alpha
Smart App (download via QR code).
multaneously, until the Power/Error LED slowly flashes
red
neously to start factory reset
neously
When the factory setting is restored on the Base
Station, the pairing of the paired room control units
is also set to the factory setting. Afterwards, pairing
with the room control units is possible again.