Descargar Imprimir esta página

Emerson AVENTICS AV-EP Serie Instrucciones De Servicio página 36

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
Pneumatics
Flow characteristic curve of the AV03-EP single pressure control
[bar]
10
9
8
7
P v = 7 bar
6
5
P v = 5 bar
4
3
2
1
0
0
200
400
Flow rate values of the AV03-EP pressure zone control
pv [bar]
p1 [bar]
11
10
11
10
7
6
7
6
Flow characteristic curve of the AV03-EP pressure zone control
[bar]
10
9
8
7
P v = 7 bar
6
5
P v = 5 bar
4
3
2
1
0
0
400
Flow rate values of the AV05-EP single pressure control
pv [bar]
p1 [bar]
11
10
11
10
7
6
7
6
Flow characteristic curve of the AV05-EP single pressure control
[bar]
10
9
8
7
P v = 7 bar
6
5
P v = 5 bar
4
3
2
1
0
0
400
800
Flow rate values of the AV05-EP pressure zone control
pv [bar]
p1 [bar]
11
10
11
10
7
6
AVENTICS™ AV-EP | R414007537-BAL-001-AB | English
P v = 11 bar
P v = 9 bar
600
800
1000
1200 [l/min]
p2 [bar]
Q [l/min]
9.8
500
9
1100
5.8
425
5
802
P v = 11 bar
P v = 9 bar
800
1200
p2 [bar]
Q [l/min]
9.8
570
9
1200
5.8
432
5
903
P v = 11 bar
P v = 9 bar
1200
1600
2000
p2 [bar]
Q [l/min]
9.8
630
9
1480
5.8
478
Pneumatics
7
Flow characteristic curve of the AV05-EP pressure zone control
Table 17: Pneumatic data
Pneumatics
Reproducibility
Hysteresis
Table 18: Electronics data
Electronics
AV-EP for fieldbus connection
Power supply
Control
AV-EP for multipole connection
Connections
Power supply
permissible ripple
Max. current consumption
Current input resistance (set point)
1600 [l/min]
Voltage input resistance (set point)
External ohmic load (current output/actual
value)
External ohmic load (voltage output/actual
value)
Switch output
Table 19: Standards and directives
Standards and directives complied with
RL 2004/108/EC
EN 61000-6-2
EN 61000-6-4
DIN EN ISO 4414
[l/min]
17 Spare parts and accessories
Information on spare parts and accessories can be found in the online catalog at
http://www.aventics.com/pneumatics-catalog.
6
5
Version: "Classic": < 0.18 bar
Version: "Smart": < 0.04 bar
Version: "Classic": < 0.2 bar
Version: "Smart": < 0.05 bar
Via the circuit board in the base plate by the
bus coupler (for the supply voltage, only use
a power pack with safe isolation)
Dependent on the fieldbus protocol
M12 connection, 5-pin, A-coded
24 V DC (+30 %/-20 %)
5 %
120 mA to 220 mA depending on the config-
uration, see the AVENTICS online catalog
Power supply switched on: 100 Ω
Power supply switched off: high-ohmic
Power supply switched on: 1 MΩ
Power supply switched off: high-ohmic
< 300 Ω
> 10 kΩ
Voltage:
Switch output = power supply - 1.8 V
Current:
Short-circuit-resistant, max. 1.4 A
"Electromagnetic compatibility" (EMC directive)
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards –
Interference immunity for industrial environments
Electromagnetic compatibility (EMC) – Part 6-4: Generic standards –
Interference emission for industrial environments
Pneumatic fluid power – General rules and safety requirements for
systems and their components
1090
36