10. Reinstall the cover plate, making sure to tighten the two screws to secure the lens
to the fixture (A).
11. Connect second conduit and conduit
connector at the junction box (Fig. 1).
NOTE: This fixture can be mounted on
1-5/8 in. diameter extension arms (not
provided). When installing fixture onto an
extension arm, remove the access cover
(C) and use the included pole mounting
clamp (H) and access cover mounting
screws (E) Mount the pole around 2.8"
(70mm) inside from edge as shown in Fig 2
12. Turn power back ON.
TROUBLESHOOTING
Problem
Cause / Solution
Light Does
No power to the fixture.
Not Come On
• Check if circuit breaker tripped.
Or Light Comes
• Confirm wall switch is ON.
On For Only A
Sensor is not working properly.
Few Seconds
• Check if light is being reflected into the sensor, causing the
fixture to turn off.
Wiring to the unit is loose.
• Confirm wiring is properly secured.
Caution: Turn off power before checking.
Light Does Not
Light sensor is not receiving enough light to trigger switch.
Shut Off During
• Shine a flashlight into the light sensor for 2-3 minutes. The
Daytime
fixture should switch off after two minutes. This means the
sensor is not receiving enough light; reposition or relocate
the fixture.
Light sensor is receiving too much reflected light.
Light Cycles
On and Off
• Cover light sensor with a piece of black electrical tape. The
fixture should turn ON after a slight delay. This means that
extraneous or reflected light from the fixture is causing the
sensor to turn the unit OFF. Install fixture where there is no
reflective light.
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT
NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
Cooper Lighting Solutions warrants to customers that, for a period of five years from
the date of purchase, Cooper Lighting Solutions products will be free from defects in
materials and workmanship. The obligation of Cooper Lighting Solutions under this
warranty is expressly limited to the provision of replacement products. This warranty is
extended only to the original purchaser of the product. A purchaser's receipt or other
proof of date of original purchase acceptable to Cooper Lighting Solutions. This is
required before warranty performance shall be rendered. This warranty does not apply
to Cooper Lighting Solutions products that have been altered or repaired that have
been subjected to neglect, abuse, misuse or accident (including shipping damages).
This warranty does not apply to products not manufactured by Cooper Lighting
Solutions which have been supplied, installed, and/or used in conjunction with Cooper
Lighting Solutions products. Damage to the product caused by replacement bulbs or
corrosion or discoloration of brass components are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL Cooper Lighting Solutions BE LIABLE FOR SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF
ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING
NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF Cooper Lighting
Solutions FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH
THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE,
REPAIR OR MODIFICATION OF Cooper Lighting Solutions PRODUCTS, OR SUPPLY OF
ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF Cooper
Lighting Solutions PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE
ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact Cooper Lighting Solutions at 1-800-334-6871,
press option 2 for Customer Service, or via e-mail ConsumerProducts@CooperLighting.
com and include the following information:
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number
issued by the Company and must be returned freight prepaid. Any product received
without a Return Goods Authorization Number from the Company will be refused.
Cooper Lighting Solutions is not responsible for merchandise damaged in transit.
Repaired or replaced products shall be subject to the terms of this warranty and are
inspected when packed. Evident or concealed damage that is made in transit should be
reported at once to the carrier making the delivery and a claim filed with them.
Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited.
For assistance, call 1-800-334-6871 or e-mail us at ConsumerProducts@cooperlighting.com
Printed in China
Fig. 2
2.8"
70
2
FRANÇAIS
ARTICLES REQUIS
(à acheter séparément)
• Tournevis cruciforme
• Clé à molette ou clé à rochet avec douille de 10 mm
• Perceuse avec foret de 3/16 po
• Conduit souple d'un diamètre de 1/2 po (au besoin, longueur selon l'installation)
• Raccords de conduit étanches de 1/2 po (au besoin)
• Capuchons de connexion
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
Des précautions de base doivent être suivies lors de l'utilisation de ce produit, incluant
• Le respect de tous les avertissements incluant les avertissements ci-dessous
ET ceux indiqués sur le produit.
• Conservez ces instructions et ces avertissements
• Exclusivement réservé à un usage extérieur
• Homologation cULus pour l'utilisation dans des endroits humides.
• Le démontage du luminaire annulera la garantie.
• Le luminaire est déjà câblé et assemblé pour faciliter son installation.
• Lisez et suivez ces instructions.
• Risque d'incendie ou de décharge électrique. Si vous n'êtes pas qualifié,
consultez un électricien.
• Mettez l'alimentation électrique hors tension depuis le fusible ou le disjoncteur
avant l'installation ou l'entretien.
• Les bords peuvent être coupants. Manipuler avec soin.
• Raccordez le luminaire à une source d'alimentation de 120 V, 60 Hz. Tout autre
raccord annulera la garantie.
• L'appareil d'éclairage doit être installé par des personnes ayant l'expérience
du câblage domestique ou par un électricien qualifié. Le système électrique
et la méthode de raccordement électrique de l'appareil d'éclairage doivent être
conformes au Code national de l'électricité et aux codes locaux du bâtiment.
• Si l'appareil d'éclairage est installé à l'envers, il peut y avoir surchauffe ou
accumulation d'eau. Installez-le à l'endroit.
DÉCLARATION DE CONFORMITÉ DE LA FCC
Le fonctionnement est assujetti aux deux (2) conditions suivantes : 1) cet appareil ne
doit pas provoquer d'interférences nuisibles et 2) cet appareil doit accepter toutes
les interférences reçues, même celles qui pourraient provoquer un fonctionnement
indésirable.
REMARQUE : Cet équipement a été mis à l'épreuve et déclaré conforme aux
limites établies pour des appareils numériques de classe B en vertu des
dispositions de l'alinéa 15 de la réglementation FCC. Ces limites sont conçues
pour assurer une protection raisonnable contre tout brouillage nuisible dans une
installation résidentielle. Cet équipement produit, utilise et peut émettre des ondes
radioélectriques. S'il n'est pas installé et utilisé conformément aux instructions, il peut
créer des parasites nuisibles aux communications radio. Cependant, il n'existe aucune
garantie que les interférences ne se produiront pas avec une installation particulière.
Si cet équipement cause des parasites nuisibles à la réception radio ou de télévision,
ce qui peut être vérifié en éteignant l'équipement et en le rallumant, il est conseillé
à l'utilisateur d'essayer de les éliminer en suivant l'une (ou plusieurs) des mesures
suivantes:
• Réorientez ou déplacez l'antenne réceptrice.
• Augmentez la distance entre l'équipement et le récepteur.
• Branchez l'équipement sur la prise électrique d'un circuit autre que celui sur
lequel le récepteur est branché.
• Demandez de l'aide au distributeur ou à un technicien radio ou TV
qualifié
AVERTISSEMENT : Les réglementations de la FCC mentionnent que toute
modification ou altération apportée à cet équipement n'étant pas expressément
approuvée par le fabricant peut annuler le droit de l'utilisateur à faire fonctionner cet
équipement.
CONSERVEZ CES INSTRUCTIONSCONSERVEZ CES INSTRUCTIONS.
MONTAGE ET CÂBLAGE DE VOTRE LUMINAIRE
AVERTISSEMENT : Risque de décharge électrique. Mettez l'alimentation électrique
hors tension depuis le fusible ou le disjoncteur avant l'installation ou l'entretien.
REMARQUE : Ce luminaire a été conçu pour être raccordé par le conduit à une boîte
de jonction en métal étanche, mis à la terre et adéquatement installé (non fourni).
Tous les conduits, raccords et boîtiers de jonction (vendus séparément)
doivent posséder l'homologation cULus pour l'utilisation dans des endroits humides.