Descargar Imprimir esta página

Argo MILO PLUS Manual De Instrucciones página 41

Ocultar thumbs Ver también para MILO PLUS:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 119
3. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select Dry.
The temperature is controlled by the PCB and cannot be regulated.
In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings
and, when switched back on again, retains them.
The fan speed is set to low and cannot be adjusted.
NOTE
The air conditioner does not cool the room when it is used as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible hose must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into the
environment.
The dehumidification mode is recommended during autumn and winter.
If used in summer, it is best to leave the flexible hose attached so that the hot air can be discharged
towards the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (consult the next chapter, "CONDENSATE
ELIMINATION").
4. VENTILATION MODE (FAN ONLY)
Press the MODE button to select Fan and wait until the relative icon appears.
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
This appliance automatically vaporises condensate in the cooling and heating mode.
When the air conditioner operates in cooling and heating mode, there is no need to drain condensate continuously; only
in certain weather conditions with very humid air may it occur that water deposits inside the unit. When its inner tank is
full, the air conditioner beeps 8 times and the message "H8" appears on the display to signal that the tank is full
and stop the appliance's operation.
Dehumidification
WARNING!
When using the air conditioner in dehumidification mode, always dispose continuous drainage, in order to maximise
dehumidification efficiency.
Use the drainage outlet on the appliance. The water can be drained into a drain by simply connecting a tube with 14
mm internal diameter (not supplied).
1. Remove the cap by turning it anti-
clockwise then remove the plug.
V 11/19
HOW TO ELIMINATE CONDENSATE
Cooling and Heating
When the unit operates in the cooling and heating mode, ensure that the
rubber cap closing the drainage opening on the back of the appliance is
properly positioned.
To empty the container, switch the air conditioner off and unplug the cord.
Remove the cap from the rear drainage opening and place its end over a
normal drain. Ensure that the tube is not twisted or bent. The tube must
slope downwards. Re-close the drainage opening with the cap, insert it into
the clamp and resume use of the air conditioner.
2. Screw the connection tube
provided turning it clockwise.
3.
Next, insert the drainage tube
into the connection tube.
41

Publicidad

loading