Descargar Imprimir esta página

Renfert ORTHO guide Set MT premium Manual Del Usuario página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
5
Operation
The handling of the orthodontic model table and the guide light can be found in the enclosed step-by-step
en
instructions.
There you will also find a link to user videos.
5.1
Switching on / off
The guide light can be switched on as soon as the power plug of the trimmer is connected.
It is switched on and off using the sensor button (4, Fig. 1).
The trimmer does not need to be running for this purpose.
6
Cleaning / Maintenance
6.1
Orthodontic model table and template
The orthodontic model table can be cleaned in the same way as the standard trimmer model table.
⇒ Remove the template.
⇒ Pull the model table upwards from the ball head at the front edge.
⇒ Clean the model table and the template using a brush as appropriate under running water.
Do not use any objects with sharp edges or solvent-based / abrasive cleaning agents.
Never use cleaning agents containing solvents or strong acids (e.g. descaling agents).
6.2
Guide light
Only wipe the housing of the guide light with a damp cloth.
Do not use any objects with sharp edges or solvent-based / abrasive cleaning agents.
7
Troubleshooting
Errors
The guide light cannot
be switched on.
The guide light does not
light up although the
trimmer is running.
8
Technical data
Supply voltage / VDC:
Current consumption / mA:
Laser:
- Laser class:
- Wavelength / nm:
- Output power P0, max. / mW:
Dimensions (width x height x depth) / mm [inch]:
Weight / g [oz]:
Cause
• The power plug of the trimmer is
not connected.
• The guide light is switched on/off
separately, independently of the
trimmer motor.
Corrective action
• Connect the power plug.
• Switch on the guide light at the sensor button (4, Fig. 1).
25 x 42 x 115 [0.98 x 1.65 x 4.53]
- 4 -
Guide light
5
30
1
650
5
40 [1.41]
Subject to change

Publicidad

loading