The owner of this equipment is responsible for ensuring that it has been
set up and adjusted by a Sunrise Medical authorized dealer under the
advice of a health care provider. It may require periodic safety and
function checks or certain in-use adjustments that can be performed by
the owner, caregiver, or a Sunrise Medical authorized dealer if desired.
Proper maintenance and cleaning may help extend the life of your
JAY back. Clean your JAY back regularly. During cleaning, component
inspection is recommended.
Check the cover for tears and excessive wear and replace if ripped, torn,
or otherwise not fully functional. If at any time, the outer cover or any
other component appears to be wearing or you notice a degradation in
the texture, contact your Sunrise Medical authorized dealer or Sunrise
Medical for evaluation and further instructions.
A. To clean the outer cover
1.
Remove the outer cover from the back shell by detaching the Velcro
and snaps.
2.
Unzip the zippers at the bottom and remove all foam components.
Then turn the cover inside out.
3.
Machine wash in warm water 50° C (122° F) and drip or tumble dry
on low heat.
4.
Ensure all foam is placed back in the proper confi guration before
using the back again.
Note: no ironing required.
Do not dry clean covers or use industrial washers and dryers to clean
cover. Do not steam autoclave. Do not bleach.
(Cushion Cover) Laundry Care Symbols
B. To clean the back shell
1.
The back shell should be wiped clean with soap and water on a
regular basis.
2.
Inspect the back shell for any loose, worn, bent, or damaged parts.
If discovered, loose, worn, or damaged parts should be replaced
before using the back support.
C. To clean the inner cover
1.
The inner cover should be wiped clean with soap and water on a
regular basis.
2.
Check the inner cover for tears and excessive wear and replace if
ripped, torn, or otherwise not fully functional.
3.
Removal and adjustment of the positioning inserts should be
performed by a health care provider experienced in seating and
positioning.
255813 Rev. A
WARNING
CAUTION
Machine wash in warm
water (50° C)
Only non-chlorine bleach,
when needed
Drip dry
Do not iron
Do not dry clean
V. MAINTENANCE AND CLEANING
D. Critical safety checks
1.
Fasteners: Sunrise Medical recommends that all fasteners be
checked for wear, such as loose bolts or broken components, every
6 months. Loose fasteners should be retightened according to the
set-up instructions.
2.
Replacing components: contact your Sunrise Medical authorized
dealer immediately to replace any components. Do not continue to
use the system after identifying worn, loose, or broken components.
E. Removal and replacement
After mounting and/or adjustment, the back can be easily removed from
the wheelchair if necessary.
1.
Removal
a.
Remove the locking pin from the mounting hardware.
b.
Push both the release levers forward to unlock the hardware.
c.
Once both levers are in the forward position, lift the back
straight up, using the handle located on the top of the back.
©
2.
Re-Attachment
a.
To re-attach the back and hardware receivers, line up the
pins to the receivers. Push the back into place on the receivers. If
properly inserted, the pins will "click" into a locked position.
b.
Insert the locking pins (A) into the mounting receiver (B). The
locking pins provide a safety feature which prevents the back
from being released unintentionally from the wheelchair.
If you are uncertain that you have heard the locking "click", pull up on the
back using the handle to test and ensure it has been securely locked.
If you fail to heed these warnings damage to your equipment, a fall, or
loss of control may occur and cause severe injury to the rider or others.
F. Accessories
The JAY FIT 2U Back is compatible with our full line of Whitmyer head
supports and select JAY thoracic laterals. Refer to the individual products
Owner's Manual and Instruction sheets for mounting, maintenance, and
cleaning instructions. Accessories should only be placed by a Sunrise
Medical authorized dealer.
8
WARNING