O P E R A T I N G I N S T R U C T I O N S | WT24-2
WT24-2R210S11: sensing range, typ. max.: 100...2000 mm on white (90% remission),
operating range or background suppression: can be adjusted between about 1200...
1600 mm, increased resistance in the event of extreme impact load.
WT24-2V550S12: M12 male connector, 5-pin, glass front screen, dynamic power heat‐
ing on the rear side of the glass, current consumption: 150 mA. The dynamic power
heating is automatically switched on and off depending on the ambient temperature
(23-26 °C). For the use of quick temperature changes in the range of <0 °C...+10 °C
WT24-2B240S13: glass front screen
WT24-2B420S14: sensing range max.: 30...3000 mm on white (90% remission), with
timer unit: adjustable 0.6...1.3 sec, glass front screen
WT24-2V510S15: M12 male connector, 5-pin: Pin1: L+, Pin2: alarm, Pin3: M, Pin4: Q
or Q/, Pin5: test input (TI)
WT24-2R210S17: sensing range, typ. max.: 100...2000 mm on white (90% remission),
operating range or background suppression: can be adjusted between about 1200...
1600 mm, increased resistance in the event of extreme impact load, PG9 connector
WT24-2R250S20: PG9 connector
WT24-2R220S21: PG9 connector
WT24-2B420S22: sensing range, typ. max.: 300...900 mm on white (90% remission),
operating range: can be adjusted between about 300...900 mm, bonding of the wires in
the terminals, with washer for cover closure
WT24-2B410S25: M12 male connector, 4-pin: Pin1: L+, Pin2 (test input); not con‐
nected Pin3: M, Pin4: Q or Q/
WT24-2B440T01: housing is coated with Teflon
The Troubleshooting table indicates measures to be taken if the sensor stops working.
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
8008784.1DMA/2022-07-12 | SICK
Subject to change without notice

Publicidad

loading