Descargar Imprimir esta página

HOLZMANN MASCHINEN STM26 Instrucciones De Servicio página 33

Publicidad

Idiomas disponibles

Idiomas disponibles

14.3
Electrical connection
Dangerous electrical voltage!
 The machine may only be connected to the mains supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
Check, whether the neutral connection and the protective grounding function properly.
Check, whether the supply voltage and the frequency correspond to the specifications of
the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
Use a supply cable of type H07RN (WDE282) or take the required cross-section of the
supply cable from a current carrying capacity table. Pay attention to the measures for
protection against mechanical damage.
Make sure that the power source is protected by a residual current circuit breaker.
Connect the device only to a properly grounded outlet.
When using an extension cable, make sure that the dimension matches the connected
load of the machine. The connection power can be found in the technical data, the
correlation of cable cross-section and cable lengths can be found in the technical literature
or obtain information from a specialist electrician.
A damaged cable must be replaced immediately.
14.4
Settings STM26S
HOLZMANN Maschinen GmbH
WARNING
Worktable tilt:
Set the worktable to exactly 90° and secure the
position with the nut (1) of the position stop (2).
Column swivel:
Set the column to exactly 90° and secure the position
with the nut (1) of the position stop (2).
www.holzmann-maschinen.at
NOTE
ASSEMBLY
33
STM26 | STM26S

Publicidad

loading

Este manual también es adecuado para:

Stm26s