Before Use - Metabo HPT CR 14DSL Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the Table 4, and batteries that have
become hot should be cooled for a while before being
recharged.
Table 4 Recharging ranges of batteries
Rechargeable
batteries
BSL1430, BSL1830,
BSL1415X, BSL1815X
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by
pulling on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the
battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the fi rst and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2 – 3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a while.
CAUTION
● When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
12
Temperatures at which the
battery can be recharged
32°F–122°F
(0°C–50°C)
charging has been completed, give 15 minutes
rest until the next charging.
● <For UC18YRSL and UC18YFSL>
If the battery is rechraged when it is warm due
to battery use or exposure to sunlight, the pilot
lamp may light in green.
The battery will not be recharged. In such a case,
let the battery cool before charging.
● <For UC18YGSL>
If the battery is charged while it is heated
because it has been left for a long time in a
location subject to direct sunlight or because the
battery has just been used, the pilot lamp of the
charger lights for 1 second, does not light for 0.5
seconds (off for 0.5 seconds).
The battery will not be recharged. In such a case,
let the battery cool before charging.
● When the pilot lamp fl ikers rapidly in red (at
0.2–second intervals), check for and take out
any foreign objects in the charger's battery
installation hole. If there are no foreign objects,
it is probable that the battery or charger is
malfunctioning. Take it to your authorized
Service Center.

BEFORE USE

Check the work area to make sure that it is clear of debris
and clutter.
Clear the area of unnecessary personnel. Ensure that
lighting and ventilation is adequate.
OPERATION
1. Mounting the blade
This unit employs a detachable mechanism that
enables mounting and removal of saw blades without
the use of a wrench or other tools.
(1) Turn on and off the switching trigger several times
so that the lever can jump out of the front cover
completely. Thereafter, turn off the switch and remove
the battery. (Fig. 6)
Lever
CAUTION
Be absolutely sure to keep the switch turned off
and the battery removed to prevent any accident.
Front cover
Fig. 6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cr 18dsl

Tabla de contenido