CONTROL BOARD FOR UP-AND-OVER DOORS
INSTRUCTIONS FOR USE- DIRECTIONS FOR INSTALLATION
1.
GENERAL FEATURES
Thanks to the high-power performance of its built-in microprocessor, this control unit for up-and-over doors offers a wide
number of services and adjustments, with slowdown and motor control. It also guarantees a high active safety level through
electronic power control.
A sophisticated electronic control constantly monitors the power circuit and blocks the control unit if faults occur which
may cause the electronic clutch to operate incorrectly.
The main settings and operating modes, time and motor power adjustments can be defined using dip-switches .
2.
TECHNICAL SPECIFICATIONS
2.1
HARDWARE SPECIFICATIONS
Power supply
Max. absorbed power
Motors max. load
Power supply for accessories
Accessories max. load
Operating ambient temperature
Protection fuses
Rapid connector
Terminal boards
Terminal board inputs
Terminal board outputs
Max. load of built-in courtesy lamp
Max. load of outside courtesy lamp
2.2
OPERATING PARAMETERS
Logic
Pause time
Operating time
Max torque at thrust
Fail safe
Pre-flashing
Electronic clutch
Limit-switch tripping modes
Courtesy timer
3.
LAY OUT OF CONTROL BOARD (fig.1)
F1
Fuse F1 5x20 5A/250V (mains circuit)
F2
Fuse F2 5x20 500mA/250V (accessories)
TF1
Transformer
LP1
Courtesy lamp 25W 230V E14
LD1
Power-supply Led
J1
230VAC power supply input terminal board
J2
Motor output terminal board, flashing lamp and outside courtesy lamp
J3
Low voltage input/accessories terminal board
J4
Rapid connector for decoding cards / 5-Pin RP receivers
DS1
Programming microswitches
for decoding cards or 5-Pin RP receivers
Open / Stop / Closing safety devices / Opening safety devices /
flashing lamp 230VAC - 40W /motor /
outside courtesy lamp 230VAC - 25W /
automatic/semi-automatic
programmable from 0 to 60 sec.
programmable from 17 to 30 sec.
fixed 0.5 sec.
Yes/No
Yes ( 5 sec.) / No
programmable on 8 levels
4 types of operation
fixed 60 sec.
5
230VAC - 50Hz
12VA
800W
24Vdc
300mA
- 20°C + 55°C
mains circuit / accessories
pull-out
Opening limit-switch / Closing limit-switch
24 Vdc accessories power supply
25W
25W
J1
PE N L
ENGLISH
1 2 3 4 5 6 7 8 9 10
J3
LP1
LD1
F2
J4
1 2 3 4 5 6 7 8 9 101112
DS1
TF1
J2
11 12 13 14 15 16
F1
Fig. 1