The products have no system for discharge of the gases released as a result of
combustion. The product should be installed and connected according to the applicable
installation regulations. Especially take care of requirements for ventilation.
Air required for combustion is taken from the room air and the released gases are
directly given into the room.
A well-ventilated room is essential for safe operation of your product. If there is no door
or door for ventilation of the room, additional ventilation should be installed.
Kitchen footprint should be more than 8m². Kitchen volume should be greater than
20m³.
Chimney outlet should be at height of 1.80 meters from the floor and open to the
atmosphere in a diameter of 150mm.
Air vent should be minimum 75cm² near the kitchen floor for opening to the
(Figure 1)
outer atmosphere.
(Figure 1)
Installation and connections
Property damage!
Do not use the door and/or handle to move or handle the product.
• It takes at least two people to carry the product.
Mounting of the legs
The legs of the product is not assembled during the installation oft he product. The legs of
the products are packed in the bag located inside the oven. ͘ ( Figure 2) Mount the legs of
your product and adjust it to the kitchen counter.
If the legs of gas ovens are not mounted, sufficiently oxygen may not be supplied to the
furnace during the use of the oven and it may disrupt the combustion.
11