Function
Pause + Restart
Recall Function
Bridge Function
Automatic pan
detection function
Residual heat indi-
cator
This function freezes all the hob settings for approximately 10 minutes if the person
using the hob needs to go away for a short time.
During the pause:
- No energy is being used in any of the cooking areas.
- All the Timers are stopped.
- The"Turbo" and "Quick Heating" functions are deactivated
When the 10 minutes are up, the hob will continue with all the actions that were set
previously.
Activation: press the button
Deactivation: press the key
seconds press any other key.
This function is used to recall all the hob function settings in the event of involuntary
shut-down or a sudden power cut.
With the hob off, if within 6 seconds the hob is turned off again using the button
, the button
flashes for 6 seconds. Press the button to recover the
functions set previously. A beep sounds to confirm the operation.
With the hob turned off, if it is turned on again within 6 seconds the previous
function settings are recovered automatically.
This function allows 2 cooking areas to be connected, so that they can be
controlled as a single, large cooking area. This means it is possible to use pans
with a larger bottom.
Attention: with the hob turned on, simultaneously press the required buttons to
select the 2 areas to form a bridge, until a Digit displays
function has been activated.
The other Digit is used to set the power level.
Caution: The left cooking areas cannot be connected to the right ones, and vice
versa.
Deactivation: press simultaneously the keys on which the bridge is created until
the symbol
disappears.
If a pan is placed on one of the cooking areas, the hob detects it automatically
and lights up the corresponding Digit at maximum intensity, displaying
The residual heat indicator is a safety feature, indicating that the surface of the
cooking area is still at a temperature of 60°C or above, which may cause burns if
touched by a naked hand.
The Digit for the corresponding cooking area displays
for at least 1 second, all Digits indicate
for at least 1 second until it flashes, within 10
to indicate that the
.
.