MD 9231 Industrial TRMS AC/DC Current Clamp Meter
AmpTip
clamp-on ACA
TM
RANGE
40 Hz ~ 100 Hz
00,00 A ~ 20,00 A
20,00 A ~ 60,00 A
100 Hz ~ 400 Hz
00,00 A ~ 20,00 A
20,00 A ~ 60,00 A
Induced error from adjacent current-carrying conductor: < 0,02 A/A.
1)
Specified with Relative Zero Δ mode applied to offset the non-zero residual readings, if any.
2)
Add 10d to the specified accuracy @ < 4 A.
3)
Regular Clamp-on ACA
RANGE
40 Hz ~ 100 Hz
60,00 A
, 600,0 A, 1000 A
2)
100 Hz ~ 400 Hz
60,00 A
, 600,0 A, 1000 A
2)
Induced error from adjacent current-carrying conductor: < 0,02 A/A.
1)
Add 10d to the specified accuracy @ < 9 A.
2)
Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale.
3)
Hz Line Level Frequency
Function
600 V, 1000V
60 A (AmpTip
TM
60 A, 600 A, 1000 A
Accuracy: 1%+5d.
DC-bias, if any, not more than 50% of Sine RMS.
1)
Non-Contact EF-Detection
Typical Voltage
20 V (tolerance: 10 V ~ 36 V)
55 V (tolerance: 23 V ~ 83 V)
110 V (tolerance: 59 V ~ 165 V)
220 V (tolerance: 124 V ~ 330 V)
440 V (tolerance: 250 V ~ 1000 V)
Indication: Bar-graph segments & audible beep tones proportional to the field strength.
Detection Frequency: 50/60Hz.
Detection Antenna: Inside the top side of the stationary jaw.
Probe-Contact EF-Detection: For more precise indication of live wires, such as distinguishing between live
and ground connections, use one single probe to test via terminal COM for direct contact EF-Detection with
best sensitivity.
3)
3)
Sensitivity
1)
50 V
)
40 A
40 A
Accuracy
1) 2) 3)
1,5% + 5d
3,0% + 5d
2,0% + 5d
3,0% + 5d
Accuracy
1)
1.8% + 5d
2.2% + 5d
(Sine RMS)
Range
5,00 Hz ~ 999,9 Hz
40,00 Hz ~ 400,0 Hz
40.00Hz ~ 400,0 Hz
Bar-Graph Indication
-
- -
- - -
- - - -
- - - - -
20
Specification

Publicidad