Quickream is supplied with a number of pre-established, default settings, which can be used for various products. The
settings are as follows:
Service step V1
Service step V2
Service step V3
RTS Time
EV OFF Time
Any modifications to these settings must be carried out by specialist and authorized personnel only.
In order to reset SERVICE menu's settings to their default, please follow below procedure:
1. Make sure the machine is turned off; main switch (page.22 pos.F) in OFF position
2. While holding
control board's screen shows
To modify the SERVICE settings, proceed as follows:
1. To view the menu options, press the
Please note that on any menu, if a key is not pressed within 30 seconds, or if the
again, the control panel will automatically exit the menu. When this occurs, the electronic control unit will
return to the previous screen.
2. Use the
or
3. Hold the
key down for at least 6 seconds or until the first option of the SERVICE submenu appears on screen.
The display will flash and show the "V1" speed at which the augers must turn when the machine is switched on
until the machine has reached the "T1"temperature.
a. Press the
or
b. Press the
setting
4. Press the
key to confirm; the display will show the second option of the SERVICE submenu.
The display will flash and show the "V2" speed at which the augers must turn once the "T1" temperature has
been exceeded. Said velocity is maintained until the "T2" temperature is reached.
It is not possible to set a "T2" temperature that is higher than the "T1" temperature.
a. Press the
or
Service submenu settings
V1= 50rpm (default)
V2= 40rpm (default)
V3= 30rpm (default)
10 minutes (default)
10 minutes (default)
button on the front control board, turn the machine back ON. Release
keys to search for the SERVICE screen.
> SERVICE
SERVICE STEP V1
V1rpm
keys to change the V1 "20 min. / max 70 in steps of 1rpm" settings.
key to switch to the next T1 "-8,5°C/16.7°F min. / max -2,5°C/27.5°F in steps of 0,5°C/0.9°F"
SERVICE STEP V2
V2rpm
keys to change the V2 "20 min. / max 70 in steps of 1rpm" settings.
T1= -3,0°C/26.6°F (default)
T2= -3,5°C/25.7°F (default)
RTS= not settable
RESET OK
key on the electronic control panel
SERVICE STEP V1
T1°C
V1rpm
SERVICE STEP V2
T2°C
V2rpm
- 32 -
T1°F
T2°F
button, when
key is pressed

Publicidad