Descargar Imprimir esta página

ELMECO Quickream Manual De Uso Y Mantenimiento página 38

Ocultar thumbs Ver también para Quickream:

Publicidad

Idiomas disponibles

Idiomas disponibles

For all manual interventions, always make sure the machine is switched off and disconnected from the
-
power supply.
The product is leaking from
the condensation outlet on
the front panel
Both in "Soft Mode" and
"Night Mode", the ice cream
production continues until
the augers lock
The product does not
thicken
The machine does not cool
and the green light on the
right side panel is OFF
The augers do not turn In
"Soft Mode", "Night Mode"
or "Motor ON" mode
The teeth of the auger
mechanism come apart until
the horizontal auger stops
completely
When turning, the horizontal
auger scrapes on the bottom
of the tank, causing noise
and vibration
The augers make a
squeaking noise when they
turn
The display shows the
warning: "Low Mix Please
Refill"
The control panel flashes,
showing the warning:
"Error:2,"
• The tank seal has not been fitted correctly in the transparent tank housing.
• The thermostat sensor is broken or has not been connected to the power supply.
The product does not reach the ideal temperature and the electronic control panel reads
"Ready to Serve". Check the TLI settings and adjust them as described on p.23.
The pressure switch has intervened. The pressure switch is equipped with automatic
reset; when the pressures have decreased, the compressor will return to operation and
the light will come on.
To avoid repeating this situation, perform the condenser cleaning procedure described on
page 26.
The rotation of the gearmotor is not being transmitted to the augers. This can be caused
by:
• a breakage of the transmission screw, no. 30 in the exploded view diagram on pag.75;
• a breakage of one or more of the auger teeth;
• A breakage of the drive shaft, no.16 in the exploded view diagram on pag.75. The
breakage could be at the top (square nut) or the bottom (inside the machine).
Make sure that the fixing seal on the vertical auger, no. 15 in the exploded diagram on
pag. 75, is attached securely.
There is not enough product in the inox tank; this leaves the rear evaporator uncovered,
with the subsequent formation of ice on the bottom of the tank. As the auger turns it
scrapes on the tank, causing noise and vibration. If this occurs refill the tank with the
relevant product.
The noise is coming from the horizontal and vertical augers. This can be stopped by
applying food-grade Vaseline to the areas shown in fig. 21 on pag.79.
This warning appears when there is not enough product in the tank. If this occurs, the
product is moved to the front of the tank, which subsequently reduces the cooling rate; to
compensate the cooling system is switched off for 5 minutes. After this time the warning
disappears and the cooling system switches back on.
• The product in the tank is colder than -8,5°C/16.7°F;
• The thermostat sensor has short-circuited.
If this occurs the cooler switches off.
- 35 -
Disconnect the
power cable from the
power supply.
Disconnect the
power cable from the
power supply.
Disconnect the
power cable from the
power supply.
Disconnect the
power cable from the
power supply.
Refill the tank.
Contact technical
support for advice.

Publicidad

loading