Descargar Imprimir esta página

Ivoclar Vivadent Programat P710 G2 Instrucciones Breves página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
Establishing the connections
G
Connect the cables of the furnace head with the furnace base.
Proceed as follows:
– Connect the vacuum hose (6).
– Insert the thermocouple plug (7). (Make sure that the polarity of
the plug is correct.)
– Insert the heater plug (8).
Insert the heater plug into the intended connector. Secure the heater
H
plug by rotating it 45°.
Closing the covering hood
I
Once all cables are correctly connected to the furnace base, close the
cover (9) to protect the connections until you feel it click into place.
Mounting the connection cover
J
The connection cover (10) can now be mounted and secured with the screws.
The furnace may only be used with the covering hood closed
and the connection cover mounted!
Establishing additional connections
K
Power connection
Make sure that the voltage indicated on the rating plate complies with the
local power supply. Subsequently, connect the power cord (11) with the
power socket of the Programat (12).
Connecting the vacuum pump
Connect the vacuum pump plug (13) with the vacuum pump socket (14).
We recommend using only a vacuum pump from Ivoclar Vivadent, since
these pumps are especially coordinated with the furnace. If other pumps
are used, please observe and do not exceed the indicated maximum power
consumption.
G
H
8
7
6
I
J
K
12
11
14
13
2
1
9
10
7

Publicidad

loading