248
0x00F8
0
NFC web link
249
0x00F9
0
Storage location
253
0x00FD
0
Installation date
Parameter
Device Settings
Commands
2
0x0002
0
System command
Access Control
90
0x005A
0
Extended device access locks
91
0x005B
0
Pin-Code NFC
Initial Settings
Blow-Off mode
69
0x0045
0
Signal type: SIO outputs of the device
73
0x0049
1
73
0x0049
2
Signal type: SIO inputs of the device
75
0x004B
0
Output filter, switch-off delay for SP2
Process Settings
Production Setup - Profile P0
Air-Saving function
68
0x0044
0
78
0x004E
0
Disable continous sucking
100
0x0064
0
Switchpoint 1 (SP1)
101
0x0065
0
Resetpoint 1 (rP1)
102
0x0066
0
Switchpoint 2 (SP2)
103
0x0067
0
Resetpoint 2 (rP2)
Duration automatic blow
106
0x006A
0
107
0x006B
0
Permissable evacuation time
108
0x006C
0
Permissable leakage rate
Profile name
119
0x0077
0
Production Setup - Profile P1
180
0x00B4
0
Air-Saving function
181
0x00B5
0
Disable continous sucking
182
0x00B6
0
Switchpoint 1 (SP1)
183
0x00B7
0
Resetpoint 1 (rp1)
184
0x00B8
0
Switchpoint 2 (SP2)
185
0x00B9
0
Resetpoint 2 (rp2)
186
0x00BA
0
Duration automatic blow
187
0x00BB
0
Permissable evacuation time
188
0x00BC
0
Permissable leakage rate
199
0x00C7
0
Profile name
Production Setup - Profile P2
200
0x00C8
0
Air-Saving function
Disable continous sucking
201
0x00C9
0
202
0x00CA
0
Switchpoint 1 (SP1)
203
0x00CB
0
Resetpoint 1 (rp1)
204
0x00CC
0
Switchpoint 2 (SP2)
205
0x00CD
0
Resetpoint 2 (rp2)
Duration automatic blow
206
0x00CE
0
207
0x00CF
0
Permissable evacuation time
208
0x00D0
0
Permissable leakage rate
Profile name
219
0x00DB
0
Production Setup - Profile P3
220
0x00DC
0
Air-Saving function
221
0x00DD
0
Disable continous sucking
222
0x00DE
0
Switchpoint 1 (SP1)
223
0x00DF
0
Resetpoint 1 (rp1)
224
0x00E0
0
Switchpoint 2 (SP2)
225
0x00E1
0
Resetpoint 2 (rp2)
226
0x00E2
0
Duration automatic blow
227
0x00E3
0
Permissable evacuation time
228
0x00E4
0
Permissable leakage rate
239
0x00EF
0
Profile name
Observation
Monitoring
System vacuum live
1
64
0x0040
2
System vacuum min
3
System vacuum max
http://...
1...64 bytes
rw
https://...
1...32 bytes
-
rw
1...16 bytes
-
rw
5, 129, 131,
1
byte
165, 167,
wo
168, 169
1
byte
0-255
rw
2
bytes
0-999
ro
1
byte
0-2
rw
1
byte
0-1
rw
1
byte
0-1
rw
2
bytes
0-999
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1
2
bytes
rw
> SP2
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1
2
bytes
rw
> SP2
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1
2
bytes
rw
> SP2
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1
2
bytes
rw
> SP2
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
https://myproduct.schmalz.com/#/
Web link to NFC app (base URL for NFC tag)
***
User string to store storage location
***
User string to store date of installation
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box (IO-Link-Communciation will be stopped, restart by
power cycle is needed)
-
0xA5 (dec 165): Calibrate all vacuum sensor
0xA7 (dec 167): Reset erasable counters
0xA8 (dec 168): Reset voltages min/max
0xA9 (dec 169): Reset vacuum min/max
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
0
Bit 3: reserved
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
0
Pin-Code for NFC write
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
0 = PNP,
0
1 = NPN
0 = PNP,
0
1 = NPN
10
Unit: 1ms
0 = not active (off)
1
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1mbar/s
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1ms,
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1ms,
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1ms
250
no leakage rate warning if set to 0
***
Name of profile
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar