1
Primary supply voltage live
66
0x0042
2
Primary supply voltage min
3
Primary supply voltage max
275
0x0113
0
Active profile
Communication Mode
564
0x0234
0
Communication mode
Diagnosis
Device Status
36
0x0024
0
Device status
37
0x0025
0
Detailed device status
130
0x0082
0
Active errors
Condition Monitoring [CM]
Condition monitoring
146
0x0092
0
Counters
Vacuum on counter
140
0x008C
0
Valve operating counter
141
0x008D
0
142
0x008E
0
Condition monitoring counter
143
0x008F
0
Vacuum on counter
144
0x0090
0
Valve operating counter
145
0x0091
0
Condition monitoring counter
Timing
148
0x0094
0
Evacuation time t0 of last suction-cycle
149
0x0095
0
Evacuation time t1 of last suction-cycle
166
0x00A6
0
Total cycle time of last cycle
Energy Monitoring [EM]
Air-Consumption of last suction-cycle
155
0x009B
0
Air-Consumption of last suction-cycle
156
0x009C
0
Energy-Consumption of last suction-cycle
157
0x009D
0
Predictive Maintenance [PM]
160
0x00A0
0
Leakage rate of last suction-cycle
161
0x00A1
0
Free-Flow vacuum
162
0x00A2
0
Quality of last suction-cycle
163
0x00A3
0
Performance of last suction-cycle
164
0x00A4
0
Max reached vacuum of last cycle
165
0x00A5
0
Min reached input pressure of last cycle
Coding of IO-Link Events
Extended Device Status ID
(= IO-Link Event Code)
dec
hex
hex
0x0000
0
0x10
20736
0x5100
0x42
20752
0x5110
0x42
20754
0x5112
0x42
4096
0x1000
0x42
6156
0x180C
0x22
0x8D00
36096
36112
0x8D10
36128
0x8D20
36144
0x8D30
36160
0x8D40
36176
0x8D50
36192
0x8D60
36208
0x8D70
36224
0x8D80
36240
0x8D90
36272
0x8DB0
2
bytes
2
bytes
2
bytes
1
byte
1
byte
1
byte
1
byte
2
bytes
2
bytes
4
bytes
4
bytes
4
bytes
4
bytes
4
bytes
4
bytes
2
bytes
2
bytes
4
bytes
1
byte
2
bytes
2
bytes
2
bytes
2
bytes
1
byte
1
byte
2
bytes
2
bytes
Extended Device Status Type
Meaning
Everything OK
(no IOL event)
Critical condition
Error
Critical condition
Warning
Critical condition
Warning
Defect/fault
Error
Warning, high
Warning
Defect/fault, low
Error
Warning, high
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Notification
Warning, low
Notification
Defect/fault, high
Error
Critical condiction, high
Warning
Warning
ro
-
ro
ro
0-3
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
-
ro
IO-Link
Event name
Event Type
Everything OK
General power supply fault
Primary supply voltage over-run
Secondary supply voltage fault
General malfunction
Primary supply voltage out of optimal range
Measurement range overrun
Valve protection active
Evacuation time t1 is greater than limit,
Leakage rate is greater than limit
SP1 was not reached
Free-flow vacuum level too high
Vacuum calibration OK
Vacuum calibration failed
Data Corruption (EEPROM)
Supply pressure fault
CM Autoset completed
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
-
Number of active profile
0x00 = SIO mode
-
0x11 = IO-Link revision 1.1
0 = Device is operating properly (= Green)
1 = Maintenance required (= Yellow)
-
2 = Out of Spec (= Orange)
3 = unused
4 = Failure (= Red)
-
Information about currently pending events (Event-List)
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
-
Bit 8 = Short circuit at OUT2
Bit 9 = reserved
Bit 10 = reserved
Bit 11 = Measurement range overrun
Bit 12 = reserved
Bit 13 = reserved
Bit 14 = reserved
Bit 15 = IO-Link communication interruption
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
-
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
Bit 8 = General input pressure out of operating range
Bit 9-15 = reserved
-
Counter for Vacuum on (non-erasable)
-
Counter for valve operating (non-erasable)
-
Counter for condition monitorings (non-erasable)
-
Counter for Vacuum on (erasable)
-
Counter for valve operating (erasable)
-
Counter for condition monitorings (erasable)
Unit: 1ms
-
Time from suction start to reaching SP2
Unit: 1ms
-
Time from reaching SP2 to reaching SP1
-
Unit: 1ms
-
Unit: 1%
-
Unit: 0.1 L std.
-
Unit: 1Ws
-
Unit: 1mbar/s
-
Unit: 1mbar/s
-
Unit: 1%
-
Unit: 1%
-
Unit: 1mbar
-
Unit: 1mbar
Remark
Device is working optimally
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Internal error, Bus fault
Condition Monitoring: primary supply voltage US outside of operating range
Vacuum value > 999 mbar in Ejector
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Internal error, user data corrupted
Input pressure too high or too low