Resetpoint 2 (rP2)
365
0x016D
0
366
0x016E
0
Duration automatic blow
367
0x016F
0
Permissable evacuation time
Permissable leakage rate
368
0x0170
0
379
0x017B
0
Profile name
Observation
Monitoring
1
System vacuum live Ejector 1
64
0x0040
2
System vacuum min Ejector 1
System vacuum max Ejector 1
3
4
System vacuum live Ejector 2
System vacuum min Ejector 2
64
0x0040
5
System vacuum max Ejector 2
6
1
Primary supply voltage live
66
0x0042
2
Primary supply voltage min
Primary supply voltage max
3
Active profile Ejector 1
275
0x0113
1
Active profile Ejector 2
275
0x0113
2
Communication mode
564
0x0234
0
Diagnosis
Device Status
Device status overall
36
0x0024
0
37
0x0025
0
Detailed device status
130
0x0082
1
Active errors Ejector 1
130
0x0082
2
Active errors Ejector 2
Condition Monitoring [CM]
146
0x0092
1
Condition monitoring Ejector 1
146
0x0092
2
Condition monitoring Ejector 2
Counters
140
0x008C
1
Vacuum on counter Ejector 1
140
0x008C
2
Vacuum on counter Ejector 2
141
0x008D
1
Valve operating counter Ejector 1
141
0x008D
2
Valve operating counter Ejector 2
142
0x008E
1
Condition monitoring counter Ejector 1
142
0x008E
2
Condition monitoring counter Ejector 2
Vacuum on counter Ejector 1
143
0x008F
1
Vacuum on counter Ejector 2
143
0x008F
2
144
0x0090
1
Valve operating counter Ejector 1
144
0x0090
2
Valve operating counter Ejector 2
145
0x0091
1
Condition monitoring counter Ejector 1
145
0x0091
2
Condition monitoring counter Ejector 2
Timing
Evacuation time t0 of last suction-cycle Ejector 1
148
0x0094
1
148
0x0094
2
Evacuation time t0 of last suction-cycle Ejector 2
Evacuation time t1 of last suction-cycle Ejector 1
149
0x0095
1
149
0x0095
2
Evacuation time t1 of last suction-cycle Ejector 2
Total cycle time of last cycle Ejector 1
166
0x00A6
1
166
0x00A6
2
Total cycle time of last cycle Ejector 2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
1
byte
0-3
ro
1
byte
0-3
ro
1
byte
-
ro
1
byte
-
ro
87
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1ms,
250
no leakage rate warning if set to 0
***
Name of profile
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
-
Number of active profile
-
Number of active profile
0x00 = SIO mode
-
0x11 = IO-Link revision 1.1
0 = Device is operating properly (= Green)
1 = Maintenance required (= Yellow)
-
2 = Out of Spec (= Orange)
3 = unused
4 = Failure (= Red)
Information about currently pending events (Event-List). For structure please see
-
IO-Link-Spec 1.1.3 chapter B.2.21. Every Error-Warning consist of 1 byte
EventQualifier and 2 bytes EventCode
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
-
Bit 8 = Short circuit at OUT2
Bit 9 = reserved
Bit 10 = Internal IO-Link communication interruption
Bit 11 = Measurement range overrun
Bit 12 = reserved
Bit 13 = reserved
Bit 14 = reserved
Bit 15 = IO-Link communication interruption
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
-
Bit 8 = Short circuit at OUT2
Bit 9 = reserved
Bit 10 = reserved
Bit 11 = Measurement range overrun
Bit 12 = reserved
Bit 13 = reserved
Bit 14 = reserved
Bit 15 = IO-Link communication interruption
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
-
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
Bit 8 = General input pressure out of operating range
Bit 9-15 = reserved
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
-
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
Bit 8 = General input pressure out of operating range
Bit 9-15 = reserved
-
Counter for Vacuum on (non-erasable)
-
Counter for Vacuum on (non-erasable)
-
Counter for valve operating (non-erasable)
-
Counter for valve operating (non-erasable)
-
Counter for condition monitorings (non-erasable)
-
Counter for condition monitorings (non-erasable)
-
Counter for Vacuum on (erasable)
-
Counter for Vacuum on (erasable)
-
Counter for valve operating (erasable)
-
Counter for valve operating (erasable)
-
Counter for condition monitorings (erasable)
-
Counter for condition monitorings (erasable)
Unit: 1ms
-
Time from suction start to reaching SP2
Unit: 1ms
-
Time from suction start to reaching SP2
Unit: 1ms
-
Time from reaching SP2 to reaching SP1
Unit: 1ms
-
Time from reaching SP2 to reaching SP1
-
Unit: 1ms
-
Unit: 1ms