Descargar Imprimir esta página

schmalz RECBi Manual De Instrucciones página 82

Publicidad

IO-Link Data Dictionary
10.02.03.00394
IO-Link Implementation
Vendor ID
Device ID
SIO-Mode
IO-Link Revision
IO-Link Bitrate
Minimum Cycle Time
Process Data Input
Process Data Output
Process Data
Process data In
Reserved
Device Status Overall
PD in byte 0
Device Status Ejector 1
SP2 (part present) Ejector 1
SP1 (air saving function) Ejector 1
PD in byte 1
SP3 (part detached) Ejector 1
CM-Autoset Ejector 1
Reserved
PD in byte 2
Errors Ejector 1 High-Byte
PD in byte 3
Errors Ejector 1 Low-Byte
PD in byte 4
Warnings Ejector 1 High-Byte
PD in byte 5
Warnings Ejector 1 Low-Byte
PD in byte 6
Vacuum Ejector 1 High-Byte
PD in byte 7
Vacuum Ejector 1 Low-Byte
Reserved
PD in byte 8
Device Status Ejector 2
SP2 Ejector 2
SP1 Ejector 2
PD in byte 9
SP3 Ejector 2
CM-Autoset Ejector 2
Reserved
PD in byte 10
Errors Ejector 2 High-Byte
PD in byte 11
Errors Ejector 2 Low-Byte
PD in byte 12
Warnings Ejector 2 High-Byte
PD in byte 13
Warnings Ejector 2 Low-Byte
PD in byte 14
Vacuum Ejector 2 High-Byte
PD in byte 15
Vakuum Ejector 2 Low-Byte
Process data Out
Vacuum Ejector 1
Blow-off Ejector 1
Setting Mode Ejector 1
CM-Autoset Ejector 1
PD out byte 0
Vacuum Ejector 2
Blow-off Ejector 2
Bits
Access
0...3
ro
4..5
ro
6..7
ro
0
ro
1
ro
2
ro
3
ro
4..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
0...5
ro
6..7
ro
0
ro
1
ro
2
ro
3
ro
4..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
0..7
ro
Bits
Access
0
wo
1
wo
2
wo
3
wo
4
wo
5
wo
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
234 (0xEA)
100281 (0x0187B9)
yes
1.1 (compatible with 1.0)
38.4 kBit/sec (COM2)
7 ms
16 bytes
4 bytes
Remark
Reserviert
00 - [green] Device is working optimally
01 - [yellow] Device is working but there are warnings
10 - [orange] Device is working but there are severe warnings
11 - [red] Device is not working properly
00 - [green] Device is working optimally
01 - [yellow] Device is working but there are warnings
10 - [orange] Device is working but there are severe warnings
11 - [red] Device is not working properly
Vacuum is above SP2 & not yet below rP2
Vacuum is above SP1 & not yet below rP1
The part has been detached after a suction cycle
Acknowledge that the Autoset function has been completed
not used
Bit 0 = Short circuit at OUT2
Bit 1 = reserved
Bit 2 = Internal IO-Link communication interruption
Bit 3 = Measurement range overrun
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = IO-Link communication interruption
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = General input pressure out of operating range
Bit 1 = reserved
Bit 2 = reserved
Bit 3 = reserved
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
System vacuum [mbar]
not used
00 - [green] Device is working optimally
01 - [yellow] Device is working but there are warnings
10 - [orange] Device is working but there are severe warnings
11 - [red] Device is not working properly
Vacuum is above SP2 & not yet below rP2
Vacuum is above SP1 & not yet below rP1
The part has been detached after a suction cycle
Acknowledge that the Autoset function has been completed
not used
Bit 0 = Short circuit at OUT2
Bit 1 = reserved
Bit 2 = reserved
Bit 3 = Measurement range overrun
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = IO-Link communication interruption
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = General input pressure out of operating range
Bit 1 = reserved
Bit 2 = reserved
Bit 3 = reserved
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 0 = Valve protection
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
Bit 5 = Primary Voltage US out of operating range
Bit 6 = reserved
Bit 7 = reserved
System vacuum [mbar]
Remark
Vacuum on/off
Activate Blow-off
Vacuum on/off with continuous suction disabled
(regardless of dCS parameter)
Perform CM Autoset function (teach permissible leakage and
permissible evacuation time)
Vacuum on/off
Activate Blow-off
RECBi MATCH 2-C
22.03.2023

Publicidad

loading