3.3 Rear panel
1
Gas fitting
2
Signal cable input
3
Power cable input
4
Water connector
Connect the coolant return hose in the cable harness
(red colour) to the appropriate fitting/coupling (red col-
our - symbol
).
5
Water connector
Connect the coolant delivery hose in the cable harness
(blue colour) to the appropriate fitting/coupling (blue
colour - symbol
3.4 Sockets panel
1
Water connector
Connect the coolant delivery hose of the torch (blue
colour) to the appropriate fitting/coupling (blue colour
- symbol
).
2
Water connector
Connect the coolant return hose of the torch (red
colour) to the appropriate fitting/coupling (red colour -
symbol
).
).
4 MAINTENANCE
Routine maintenance must be carried out on the
system according to the manufacturer's instruc-
tions.
Any maintenance operation must be performed by qualified
personnel only.
When the equipment is working, all the access and operating
doors and covers must be closed and locked.
Unauthorized changes to the system are strictly forbidden.
Prevent conductive dust from accumulating near the louvers
and over them.
Disconnect the power supply before every opera-
tion!
Carry out the following periodic checks on the
power source:
- Clean the power source inside by means of
low-pressure compressed air and soft bristle
brushes.
- Check the electric connections and all the con-
nection cables.
For the maintenance or replacement of torch components,
electrode holders and/or earth cables:
Check the temperature of the component and
make sure that they are not overheated.
Always use gloves in compliance with the safety
standards.
Use suitable wrenches and tools.
Failure to carry out the above maintenance will invalidate all
warranties and exempt the manufacturer from any liability.
25