4
SYSTEM SPECIFICATIONS
System Specifications
Max Flow Rate @
Model No.
30 mJ/cm²
522635
25 GPM
522636
45 GPM
522637
62 GPM
522638
100 GPM
Sizing Chart
Max Flow Rate @
Model No.
30 mJ/cm²
522635
25 GPM
522636
45 GPM
522637
62 GPM
522638
100 GPM
Est. Lamp Life* (years)
NOTE (*): Lamp life estimates given above are based on a system that is in continuous operation, 365 days a year. Actual lamp life will vary based
on specific operation schedules.
PRE-INSTALLATION INSPECTION
Quartz Sleeve and UV Lamp Inspection
NOTE: DO NOT handle the lamp or quartz sleeve with bare hands. Your
hands can deposit oils on the quartz sleeve and lamp that will decrease
the efficiency of the UV.
1. Carefully unpack the UV lamp and quartz sleeve from their corrugated
packing tube and inspect for damage including broken glass, cracks,
chips, fractures and pin holes. If damage has occurred please contact
the place of original purchase immediately.
BIOSHIELD® UV SYSTEM Installation and User's Guide
Lamp
Wattage
Amperes (A)
50
0.98-0.43
80
0.98-0.43
120
0.98-0.43
150
1.82-0.91
Turnover Rate in GPM Determined by Daily Hours of Operation
6
8
10
9,000
12,000
15,000
16,200
21,600
27,000
22,320
29,760
37,200
36,000
48,000
60,000
5.5
4.1
3.3
UV-C Output
Dimensions
Watts
W x H (Inches)
15
28" x 5.75"
27
43" x 5.75"
36
56" x 5.75"
57
70" x 5.75"
Hours
12
14
16
18,000
21,000
24,000
32,400
37,800
43,200
44,640
52,080
59,520
72,000
84,000
96,000
2.7
2.3
2.1
NOTE: Save the corrugated lamp packaging after unpacking the
UV lamp. Storing the lamp and/or quartz sleeve in this packaging
while performing maintenance on the UV system will protect these
components from damage or fouling when outside of the vessel.
2. After inspection, assemble the quartz sleeve into the UV vessel. If
installing the unit, perform the Mandatory Leak Test (see page 6).
3. Inspect all other UV system components (power supply, UV vessel
unions and necessary mounting clamps) for damage.
After receipt and inspection of the unit, if broken glass is found
(including cracks, chips, pin holes and hair line fractures of any kind)
please contact Pentair Water Pool and Spa, Inc. at (800) 831-7133.
Input Voltage
Pressure Loss
120/240 VAC
Less than
50/60 Hz
0.5 PSI
120/240 VAC
Less than
50/60 Hz
0.5 PSI
120/240 VAC
Less than
50/60 Hz
0.5 PSI
120/240 VAC
Less than
50/60 Hz
0.5 PSI
18
20
22
27,000
30,000
33,000
48,600
54,000
59,400
66,960
74,400
81,840
108,000
120,000
132,000
1.8
1.6
1.5
24
36,000
64,800
89,280
144,000
1.4

Publicidad

loading

Este manual también es adecuado para: