INSTALLATION INSTRUCTIONS
C-WR-A-WW4-SCCT LED Series
PENDANT MOUNT INSTALLATION
Position the fixture on a flat surface, lens side up. See Figure 1.
1.
Gently press down on the center of the lens near one of the
2.
fixture end caps. Deflect the lens approximately 1" to reveal a limit
bracket in the end cap. Slide the lens under the limit bracket. This
will allow the opposite end of the lens to become free and lift out.
See Figure 2.
Lift the opposite end of the lens and slide the lens out of the
3.
fixture. Set the lens aside for later use. See Figure 3.
Remove the appropriate knockouts at the ends of the fixture for
4.
pendant attachment points. See Figure 9.
Attach customer supplied 1/2" conduit to support the fixture at both
5.
ends.
NOTE: Conduit spacing should be 43-19/64" (1100 mm) on center.
Secure the fixture to the conduit using (2) customer supplied
6.
conduit locknuts per conduit location. On each conduit section,
one locknut should be positioned on top of the fixture and one
inside the fixture. See Figure 10.
Route the supply leads through one of the pieces of conduit and
7.
into the fixture. Wire the fixture per the appropriate Electrical
Connections section.
NOTE: If using the occupancy sensor accessory, please refer
to Occupancy Sensor Accessory section for installation and
programming of occupancy sensor before proceeding to the
Electrical Connection section.
Select desired wattage and CCT on driver. See Figure 6.
8.
Reinstall the lens by inserting one end of the lens into either fixture
9.
end caps. Gently press down on the center of the lens near the
end cap to deflect it about 1", allowing it to clear the limit bracket.
Slide the lens as far as possible into the end cap, keeping the lens
under the limit bracket. Fit the opposite end of the lens into the
fixture. See Figure 7.
10. Once the lens is fully fitted in the fixture, slide the lens towards the
opposite end of the fixture to lock the lens in place. See Figure 8.
11. Supply power to fixture.
OCCUPANCY SENSOR ACCESSORY
(Requires use of C-ACC-MW-L Accessory)
NOTE: When the occupancy sensor is used, dimming is controlled
by the occupancy sensor.
Remove one 1/2" knockout from the end cap at the selected end
1.
of the fixture.
Mount the sensor to the end cap by passing the sensor wires
2.
and threaded nipple through the 1/2" knockout opening. Secure
the sensor in place using the conduit nut on the nipple inside the
fixture end cap.
Refer to instructions included with sensor for setting dip switches
3.
to program sensor
http://lighting.cree.com/warranty
Document:
LPN00867X0001A1_A
Created By:
TMT
FIGURE 5
FIGURE 6
NOTE: Factory settings are 55W , 4000K
FIGURE 7
FIGURE 8
|
866.924.3645
Date:
12-08-2021