2.0 - INSTALLATION
2.4 - Mounting
The thickness of the panel on which the gauge will be mounted must be between 0.5 mm and 18 mm.
Ø 52 mm
0,5...18 mm
A
0,5...8 mm
B
16
1) Drill a circular hole (Ø 52 mm) in the area where the gauge will be installed.
WARNING: drill the hole according to the indicated measurement. Enlarge and finish,
if necessary, with conical drill bits, a file, or sandpaper. Deburr the edges.
WARNING: an oversized hole in the panel may compromise
the seal of the rubber gasket (O-ring).
2) Position the rubber gasket in the gauge and insert it in the hole from the front.
Make sure the seal is properly compressed between
the panel and the front ring on the gauge.
3) Choose the installation direction of the ring-nut (A or B) based on the thickness
of the panel, as shown in the figure.
Manually screw and tighten the ring-nut carefully on the gauge.
WARNING: excessive tightening torque may cause damage to the casing
and compromise the seal of the rubber gasket
4) Insert the connector in the outlet on the back of the gauge.
Comply with the insertion key.
Press on the connector until it clicks in place.