4) lift the recovery tank, by making it turn backwards around about 90 : in this way you
have access to the battery compartment (embedded in the solution tank) from the
upper side;
5) insert the batteries in the compartment, orienting them as shown in the drawing printed
on the solution tank in the compartment.
Install the storage batteries on the machine using suitable means according to
Positive and negative poles have different diameters.
6) Referring to the arrangement of cables in the aforesaid drawing, connect the clips of the
battery wiring and the bridge to the poles of the storage batteries. After orienting the
cables as shown in the drawing, tighten the clips at the poles and cover them with
vaseline;
7) insert back the tank unit in its work position and hook it to the solution tank;
8) after having checked that all switches on the control panel are at the position "0" (off),
connect the battery wiring connector (fig. 5, ref. 2) to the machine wiring connector (fig.
5, ref. 1);
9) use the machine in compliance with the instructions written below.
5.6
The battery-charger (models with battery)
Never let the batteries run down excessively, as they could become damaged
5.6.1 Choosing the battery-charger
Check that the battery-charger is compatible with the batteries to be charged:
− tubular lead batteries: an automatic battery-charger 24V - 20A is suggested. Anyway,
refer to the Manufacturer and read the relative manual to confirm your choice;
− gel batteries: use a battery-charger specifically intended for this type of storage
batteries.
5.6.2 Preparing the battery-charger
If you wish to use a battery-charger not supplied with the machine, it is necessary to
mount on it the connector delivered with the machine (see paragraph "Unpacking" of this
manual).
To install the connector proceed as follows:
• remove about 13 mm of sheath from the black and red cables of the battery-charger;
• insert the cables in the connector pins and push strongly with suitable pliers;
insert the cables in the connector respecting the polarity (red cable +, black cable –).
5.7
Lifting and handling the machine
All stages must be performed in an adequately lighted environment adopting all
Always wear individual protections for the user's safety.
The loading of the machine onto a vehicle must be done as follows:
empty the recovery tank and the solution tank;
remove the squeegee and the brushes (or drive discs);
remove the batteries (in models with battery);
WARNING
their weight.
WARNING
irreparably.
WARNING
necessary safety measures.