23. If necessary, put the covering cap on the drinking valve.
24. Attach the inner mask.
25. Fit the mouthpiece if necessary.
3.14 Replacing the drinking valve
(FPS 7000 RP)
1. Remove the mouthpiece.
2. Disconnect the inner mask.
3. Remove the covering cap of the drinking valve and then
remove it from the cap together with the frame.
4. Loosen the screws (see figure F-1 on the fold-out page)
and remove the wiper handle (see figure E-6 on the fold-
out page).
5. Unhook the cap from the visor frame, then remove it from
the front port by pulling it upwards over the drinking valve.
6. Swivel the drinking valve downwards approx. 180°, then
pull it out of the front port.
7. Attach a new drinking valve to the front port so that it
points downwards.
8. Turn the drinking valve back and forth to fix it in the front
port, so that the safety lug of the drinking valve grips below
the safety lug of the front port.
9. Turn the drinking valve upwards to the end stop.
10. Hook the cap into place on the button and place it on the
drinking valve, then hook it into the visor frame.
11. Pull the covering cap of the drinking valve with the frame
over the drinking valve and mount it to the cap.
12. Mount the wiper handle, then fasten the three screws
(recommended torque: 60+5 Ncm).
®
13. Use Loctite
221 to secure the screw at the wiper handle.
14. Put the covering cap on the drinking valve.
15. Attach the inner mask.
16. Mount the mouthpiece.
4
Storage
FPS 7000
● Loosen the head harness as far as possible.
● Make sure that the facepiece is dry.
● Pack the full face mask in its bag or carrying box.
● Store the full face mask in a dry, dust-free place where it
cannot become deformed.
● Protect from direct sunlight and thermal radiation.
● Storage temperature: -15 °C to +25 °C
● Observe ISO 2230 and national regulations concerning
the storage, maintenance, and cleaning of rubber
products.
Dräger rubber products are treated with an agent to protect
against premature ageing which in some cases is visible as a
grey-white coating. This coating can be washed off with a
brush and soapy water.
5
Disposal
Dispose of the product in accordance with the applicable rules
and regulations.
Technical manual
|