AUDIBLE CONTINUITY TEST
1. Connect the black test probe to the "COM" connector and the RED to the
"
" connector. (Note: The polarity of the red test probe is positive
"+").
2. Set the function switch to the "
" range.
3. Press the "SELECT" button to select the audible continuity test
selection mode. The "
" symbol will appear as an indicator.
4. Connect the test probes through the load to be measured.
5. If the circuit resistance is less than 30
, the interlocked buzzer will
buzz.
DIODE TEST
1. Plug the BLACK test probe into the "COM" connector and the RED
connector into "
". (Note: The polarity of the red test probe is
positive "+".
2. Set the function switch to the "
" range
3. Press the "SELECT" button to select the continuity measurement mode.
The symbol "
" will appear as an indicator.
4. Connect the red test lead to the anode of the diode to be tested and the
black test probe to the cathode.
5. The multimeter will show the direct voltage of the diode. If the
connections are reversed, "OL" will be shown on the display.
TEMPERATURE MEASUREMENT
1. Set the function range switch to the "TEMP" position.
2. Confirm that the polarity of the thermocouple probe is correct; place the
cold end (free end) of the thermocouple probe in the terminal (black on the
"COM" connector and red on the "ºC" connector).
3. Place the thermocouple on or in the object to be tested.
4. The temperature value is shown on the display in degrees Celsius (ºC).
5. Press the "SELECT" button, Fahrenheit and Celsius to convert the
values.
CAPACITANCE MEASUREMENT
1. Plug the BLACK test lead into the "COM" connector and the RED test lead
into the "
" connector.
2. Set the function switch "
" to the position. (NOTE: The polarity of
the RED test probe is positive "+").
3. Connect the test leads through the capacitor being measured and
confirm that the polarity of the connection is correct.

Publicidad