When the capacitance being measured is above 100 µF, it needs at least 5
seconds to stabilize the reading.
FREQUENCY MEASUREMENT (Automatic Range)
NOTE
1. Set the range function switch to the required "Hz / Duty" position.
2. Plug the BLACK test probe into the "COM" connector and the RED test
probe into the "
("+").
3. Connect the test probes through the load to be measured.
NOTE
Do not apply more than 250 V RMS at the input. Voltages higher than 100 V
RMS may be indicated, but the reading may be out of range.
While using the clamp to test AC current, press the "
the clamp, the multimeter will display the frequency of the measured
current.
NOTE
The test temperature is displayed when the thermocouple probe is placed
in the test holes.
The surrounding temperature is displayed when the sensor circuit is cut
off.
• The temperature limit measured by the thermocouple probe together with
the multimeter is 400 ºC maximum in short periods, in case you need to
measure higher temperatures you should acquire a thermocouple probe
with a higher capacity.
7. AUTOMATIC SHUT OFF
If the multimeter is not operated for about 15 minutes, it turns off
automatically. To turn it back on, just turn the range switch
8. BATTERY REPLACEMENT
If the "
" symbol appears on the display, it indicates that the battery needs
to be changed. Remove the screws and open the back of the housing.
Replace the battery with a new one.
Uses 1 6F22 9V DC Carbon-Zinc battery (included).
" connector. Note: Test probe polarity is positive
" button and open